80 SERIES

OM--00955

PAGE A -- 1

SAFETY

SAFETY --- SECTION A

This information applies to 80 Series

Engine Driven pumps. Refer to the man-

ual accompanying the engine before at-

tempting to begin operation.

Because pump installations are seldom

identical, this manual cannot possibly

provide detailed instructions and pre-

cautions for each specific application.

Therefore, it is the owner/installer’s re-

sponsibility to ensure that applications

not addressed in this manual are per-

formed only after establishing that nei-

ther operator safety nor pump integrity

are compromised by the installation.

Before attempting to open or service the

pump:

1. Familiarize yourself with this man-

ual.

2. Switch off the engine ignition and

disconnect the positive battery

cable to ensure that the pump will

remain inoperative.

3. Allow the pump to completely cool

if overheated.

4. Check the temperature before

opening any covers, plates, or

plugs.

5. Close the suction and discharge

valves.

6. Vent the pump slowly and cau-

tiously.

7. Drain the pump.

If the pump is equipped with the option-

al automatic starting system, it is sub-

ject to automatic restart. Keep hands

and clothing away from the unit to pre-

vent injury during automatic operation.

Disconnect the positive battery cable

before performing any maintenance.

Failure to do so may result in serious

personal injury.

This pump is designed to handle most

non-volatile, non-flammable liquids

containing specified entrained solids.

Do not attempt to pump volatile, corro-
sive, or flammable materials, or any liq-

uids which may damage the pump or en-

danger personnel as a result of pump

failure.

Use lifting and moving equipment in

good repair and with adequate capacity

to prevent injuries to personnel or dam-

age to equipment. Suction and dis-

charge hoses and piping must be re-

moved from the pump before lifting.

After the pump has been positioned,

make certain that the pump and all pip-

ing or hose connections are tight, prop-

erly supported and secure before oper-

ation.

Do not operate the pump against a

closed discharge valve for long periods

of time. If operated against a closed dis-

charge valve, pump components will

deteriorate, and the liquid could come

to a boil, build pressure, and cause the

pump casing to rupture or explode.