beautypg.com

Gorman-Rupp Pumps T6A60S-F4L 1263998 thru 1313298 User Manual

Page 45

background image

OM−05514

SUPER T SERIES

MAINTENANCE & REPAIR

PAGE E − 16

When installing the shaft and bearings into
the bearing bore, push against the outer
race. Never hit the balls or ball cage.

Position the outboard oil seal (19) on the lubricated
shaft with the lip positioned as shown in Figure 4.
Press the oil seal into the bearing housing until the
face of the seal is just flush with the machined sur-
face on the bearing housing.

Press the oil seal (13) into the drive flange (10) with
the lip positioned as shown in Figure 4. Replace
the flange gasket (17), and secure the flange to the
bearing housing with the hardware (15 and 16). Be
careful not to damage the oil seal lip on the shaft
keyway.

Lubricate the bearing housing as indicated in LU-
BRICATION.

Seal Installation

(Figures 4, 8, 9 and 10)

Most cleaning solvents are toxic and

flammable. Use them only in a well ven-
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain-
ers.

Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent. Inspect the stationary
seat bore in the seal plate for dirt, nicks and burrs,
and remove any that exist. The stationary seat bore
must be completely clean before installing the
seal.

A new seal assembly should be installed
any time the old seal is removed from the
pump. Wear patterns on the finished faces
cannot be realigned during reassembly.
Reusing an old seal could result in prema-
ture failure.

To ease installation of the seal, lubricate the shaft
sleeve O-ring (30) and the external stationary seat
O-ring with a very small amount of light lubricating
oil. See Figure 8 for seal part identification.