Gorman-Rupp Pumps PA10A60-4045H-ESP 1485220 and up User Manual
Page 43
OM-06351
PA SERIES
MAINTENANCE & REPAIR
PAGE E - 23
Using a suitable lifting device, position the as
sembled rotating assembly and coupling so the
flexible portion of the coupling seats inside the out
er ring attached to the flywheel.
NOTE
To ease installation, lightly lubricate the rubber por
tion of the coupling with a non‐petroleum based
lubricant such as vegetable oil or glycerin, or a sili
con‐based lubricant such as “WD40” or equivalent.
Do not use petroleum‐based lubricants, or any oth
er substance which may soften or otherwise dam
age the rubber.
Secure the intermediate to the bellhousing with the
previously removed hardware (5 and 6). Make sure
the intermediate guards (not shown) are installed
over the openings in the intermediate.
Seal Reassembly and Installation
(Figures 6 and 9)
Clean the seal cavity and shaft with a cloth soaked
in fresh cleaning solvent.
Most cleaning solvents are toxic and
flammable. Use them only in a well ven
tilated area free from excessive heat,
sparks, and flame. Read and follow all
precautions printed on solvent contain
ers.
The seal is not normally reused because wear pat
terns on the finished faces cannot be realigned
during reassembly. This could result in premature
failure. If necessary to reuse an old seal in an emer
gency, carefully wash all metallic parts in fresh
cleaning solvent and allow to dry thoroughly.
Handle the seal parts with extreme care to prevent
damage. Be careful not to contaminate precision
finished faces; even fingerprints on the faces can
shorten seal life. If necessary, clean the faces with a
non‐oil based solvent and a clean, lint‐free tissue.
Wipe lightly in a concentric pattern to avoid
scratching the faces.
Inspect the seal components for wear, scoring,
grooves, and other damage that might cause leak
age. Clean and polish the shaft sleeve, or replace it
if there are nicks or cuts on either end. If any com
ponents are worn, replace the complete seal;
never mix old and new seal parts.
If a replacement seal is being used, remove it from
the container and inspect the precision finished
faces to ensure that they are free of any foreign
matter.
To ease installation of the seal, lubricate the O‐
rings and bellows with water or a very small
amount of oil, and apply a drop of light lubricating
oil on the finished faces. Assemble the seal as fol
lows, (see Figure 9).