OM−04402

PA SERIES PUMPS

PAGE B − 4

INSTALLATION

temporarily in a slurping" application with varying
water levels.

NOTE

The pipe submergence required may be reduced

by installing a standard pipe increaser fitting at the
end of the suction line. The larger opening size will
reduce the inlet velocity. Calculate the required
submergence using the following formula based
on the increased opening size (area or diameter).

Figure B−1. Recommended Minimum Suction Line Submergence vs. Velocity

DISCHARGE LINES

Siphoning

Do not terminate the discharge line at a level lower
than that of the liquid being pumped unless a si-
phon breaker is used in the line. Otherwise, a si-
phoning action causing damage to the pump
could result.

Valves

This pump is designed with a check valve in the
discharge line.

If a throttling valve is desired in the discharge line,
use a valve as large as the largest pipe to minimize
friction losses. Never install a throttling valve in a
suction line.

With high discharge heads, it is recommended that
a throttling valve be installed in the discharge line
to protect the pump from excessive shock pres-
sure and reverse rotation when it is stopped.

If the application involves a high discharge
head, gradually close the discharge
throttling valve before stopping the pump.

ALIGNMENT

Engine Driven Units

The alignment of the pump, air compressor and
engine is critical for trouble-free mechanical opera-