Safety ‐ section a – Gorman-Rupp Pumps UNIT 608-A 1395614 and up User Manual
Page 6
UNIT SERIES
OM-01238
PAGE A - 1
SAFETY
SAFETY ‐ SECTION A
This information applies to operation
and maintenance of the UNIT 608-A
tankleenor. Refer to the manual accom
panying the electric motor before at
tempting to begin operation.
Because pump installations are seldom
identical, this manual cannot possibly
provide detailed instructions and pre
cautions for each specific application.
Therefore, it is the owner/installer's re
sponsibility to ensure that applications
not addressed in this manual are per
formed only after establishing that nei
ther operator safety nor pump integrity
are compromised by the installation.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man
ual.
2. Unplug the motor to ensure that
the pump will remain inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Vent the pump slowly and cau
tiously.
6. Drain the pump.
This pump is designed to handle water,
gasoline or other petroleum products.
Do not attempt to pump corrosive or
highly volatile liquids which may dam
age the pump or endanger personnel as
a result of pump failure.
Before operating or servicing the pump,
be certain proper safety practices are
followed. Provide adequate ventilation,
prohibit smoking, wear static‐resistant
clothing and shoes. Clean up all fuel
spills immediately after occurrence.
Connect the ground wire to the tank fill
pipe or other ground connection before
operating the unit. Static electric build‐
up could develop during cleaning op
eration, causing hazardous sparks.
Do not operate the pump against a
closed eductor control valve for long
periods of time. This could bring the liq
uid to a boil, build pressure, and cause
the pump casing to rupture or explode.
Overheating may produce dangerous
fumes. Use extreme caution when vent
ing the pump, or when removing covers,
plates, plugs or fittings.
Overheated pumps can cause severe
burns and injury. If overheating of the
pump occurs:
1. Stop the pump immediately.
2. Allow the pump to completely cool
if overheated.
3. Refer to instructions in this manual
before re‐starting the pump.