Gorman-Rupp Pumps UNIT 608-A 1395614 and up User Manual
Page 15
OM-01238
UNIT SERIES
OPERATION
PAGE C - 2
Liquid Temperature And Overheating
The maximum liquid temperature for this unit is
160
_ F (71_C). Do not apply it at a higher operating
temperature.
Overheating can occur if operated with the eductor
valve in the shutoff position for an extended period
of time. Operating against a closed valve could
bring the liquid to a boil, build pressure, and cause
the pump to rupture or explode. If overheating oc
curs, stop the pump and allow it to completely cool
before servicing it. Refill the pump casing with cool
liquid.
Do not operate the pump against a
closed eductor control valve for long
periods of time. If operated against a
closed eductor control valve, pump
components will deteriorate, and the
liquid could come to a boil, build pres
sure, and cause the pump casing to rup
ture or explode.
OPERATION
Refer to INSTALLATION, Section B for proper set
up of the cleaning system.
Turn the eductor valve to the shutoff position See
Figure 1 for the three positions of the eductor valve.
Do not operate the pump against a
closed eductor control valve for long
periods of time. If operated against a
closed eductor control valve, pump
components will deteriorate, and the
liquid could come to a boil, build pres
sure, and cause the pump casing to rup
ture or explode.
a) Shutoff
b) Vacuum
c) Backflush
Figure 1. Eductor Valve Positioning
Turn the power switch on and rotate the eductor
valve to the vacuum position (Figure 1‐b). Observe
the sight glass on the reel assembly. As soon as liq
uid appears, the tankleenor is ready for operation.
Slowly push the hose along the bottom of the tank.
Dirt and contaminates will appear in the sight glass
as they are removed. Stop feeding the hose into
the tank until the sight glass clears, then continue
feeding the nozzle along the bottom of the tank un
til resistance is felt, indicating that the nozzle has
contacted the end of the tank.
A very slight movement of the reel and
standpipe assembly results in much great
er movement of the hose and nozzle. Use
extreme caution when repositioning the
reel and standpipe to prevent tangling the
hose.