beautypg.com

Terminating the cable with bnc connectors, Terminating the cable with f-type connectors – Extron Electronics CTU 100 User Manual

Page 3

background image

Plastic

Dielectric

Sleeve

Compression

Sleeve

Center

Pin

Mini HR/

Mini 59

SuperFlex

Cable

1

2

3

5

5

4

Optional

Color

Ring

Compression

Connector

BNC Front

Ring

RG59 HR
Plenum
Cable

Center
Conductor

Optional
Color
Ring

5

RG59 HR
(Non-plenum)/
RG6 SHR
Plenum or
Non-plenum
Cable

Center
Conductor

Optional
Color
Ring

Compression
Connector

Inner Sleeve

Inner Sleeve goes

over the dielectric and

under the braid.

Use compression

tool for leverage

Plastic
Slug
(discard)

RG59/RG6

Cable

Center Pin

Dielectric

Dielectric is
flush with inner
sleeve top.

Optional
Color
Ring

1

Terminating the Cable with BNC connectors

1

.

Mini HR and Mini 59 cable only —

Slide

the center conductor pin onto the center
conductor.

2

.

Mini HR and Mini 59 cable only —

Place

the plastic dielectric sleeve over the center
conductor pin.

3

.

Mini HR and Mini 59 cable only —

Slide

the compression sleeve over the dielectric
sleeve as far as possible.

4

.

RG 59 HR plenum cable only —

Slide the

barrel over the braid and outer insulation.

CAUTION

For RG 59 HR plenum cable,
ensure that the foil slides
cleanly into the ferrule and
does not bunch up. If the foil
does bunch up, you must cut
and restrip the cable and start
over.

5

.

Push the compression connector onto the
cable, gently twisting the cable in the
compression connector, until the center pin is flush with the BNC
front ring.

6

.

Place the cable and connector in the opened compression tool (no
adapter is necessary).

7

.

Compress the cable and connector together, as shown on page 2.

Terminating the Cable with F-type connectors

1

.

Push the compression connector onto the cable until
the dielectric is flush with the inner sleeve top of the
connector. Use the compression tool to provide
leverage as shown. The center conductor should
protrude slightly from the front ring

. Discard the

plastic slug.

2

.

Select and place the correct adapter into the
compression tool. Use the gold adapter for gold
connectors and the silver adapter for nickel
connectors.

CAUTION

Using the wrong adapter can damage the
tool and/or the connector.

3

.

Place the cable and connector in the opened
compression tool.

4

.

Compress the cable and connector together, as shown
on page 2.

RG59
Plenum
Cable

Coax Foil

Foil must go inside

compression sleve.

Compression
Sleve

3

CTU 100 Universal Termination Compression Tool