beautypg.com

Initial setup — before you connect to a, Network, Step – Extron Electronics VN-Matrix 300 Setup Guide User Manual

Page 2: Intial setup — before you connect to a network, Vn-matrix 300 • setup guide, Initial setup — before you connect to a network

background image

2

Initial Setup — Before You Connect to a Network

NOTE

: You need to manually assign a known IP address for the controller into each VN-Matrix 300 unit. Extron recommends that

you use a static IP address scheme rather than DHCP.

Before connecting each VN-Matrix 300 unit to the network (connectors

c

and

d

), change the network settings of the units.

z

For an open network, contact the system administrator for a range of IP addresses.

z

For a network dedicated exclusively to the VN-Matrix 300 (preferred), Extron recommends that you use addresses in the range
of 192.168.0.1 through 192.168.0.254, with a subnet mask (netmask) of 255.255.255.0.

One VN-Matrix unit must be designated as a controller. All normal system configuration and control is via the network interface for
which the controller functions as a network server. The controller can be any unit in the system, whether configured as an encoder
or decoder.
In figure 1 on page 1, the VN-Matrix 300 unit at 192.168.0.101 is designated as the controller. Each VN-Matrix 300 device in the
system should be set to recognize the IP address of the device controller.
Change the network settings for all units as follows:

1.

Connect a PC to the Com 1 port (

a

) on the unit to be set.

2.

To initiate communication between the computer and the VN-Matrix 300 unit, run HyperTerminal from the PC. Set the
communications settings as follows:
Baud rate: 115200

Data bits: 8

Parity: None

Stop bits: 1

Flow control: None

3.

Connect the power supply to the VN-Matrix 300 unit (

e

). When the boot up is completed, a message similar to as shown below

appears:

eth1: IBM EMAC: link up, Unknown speed/duplex.
eth1: IBM EMAC: MAC 00:e0:aa:11:00:38.

4.

Press . The connected unit responds with the prompt login:.

5.

Type the default login config and press . The connected unit responds with the prompt password:.

6.

Type the default password config and press . The connected unit downloads the configuration menu.

Network Port 1 Network Port 2

============== ==============

0. Speed/Duplex: auto_10_100_1000 10. Speed/Duplex: fibre_fixed_1000F
1. Boot method: static [dhcp] 11. Boot method: static [dhcp]
2. address: 192.168.0.104 12. address: 192.168.1.2
3. netmask: 255.255.255.0 13. netmask: 255.255.255.0
4. gateway: 14. gateway:
5. broadcast: 15. broadcast: 192.168.1.255
6. mtu: 1500 16. mtu: 1500
7. controller ip: 192.168.0.101 17. ip forwarding: 0
8. controller port: 80 18. webserver port: 80
9. Exit

Please select an option:

RJ-45 Network Port ( )

Optical Network Port ( )

3

4

NOTE

: Many menu selections are not available if DHCP is selected. Select 1 or 11 to toggle DHCP on and off.

7.

Change the settings as needed as follows:

NOTES:

Do not include leading zeros when typing IP addresses. For example, type 192.168.0.104; do not type 192.168.000.104.

Settings that you may need to change are:

z

Address (selection 2 or 12)

z

Netmask (selection 3 or 13)

z

Controller IP (selection 7)

a.

Type the option number and .

b.

Type the new setting and .

c.

Once all the changes have been made, type 9 and to save the settings and exit the menu.

8.

Repeat steps 1 through 7 for each VN-Matrix 300 unit in the system.

VN-Matrix 300 • Setup Guide