beautypg.com

Connections, Front panel controls and indicators, Specifications – Extron Electronics MSW 4V SDI User Guide User Manual

Page 4

background image

VersaTools™ MSW 4V SDI Mini Switcher • Specifications

7

VersaTools™ MSW 4V SDI Mini Switcher • Controls and Indicators

Connections

6

To verify the polarity before connection, check the no load power
supply output with a voltmeter.

Alternatively, an Extron P/S 100 Universal 12VDC Power Supply
can power up to ten MSWs or other Extron 12V DC devices using
only one AC power connector.

Front Panel Controls and Indicators

A/V SWITCHER

MODE

NORMAL

AUTO

AUTO

SWITCH

1

2

3

4

10

5

6

7

8

9

Figure 6 — MSW 4V SDI front panel

Input selection

5

Input 1 through 4 buttons —

Each Input button selects the

associated input for output.

The Input 1, Input 2, and Input 3 buttons are also used to toggle
auto-switch mode on and off. See Autoswitch mode controls and
indicators
and items

7

,

8

, and

9

.

6

Input 1 through 4 LEDs —

The Input LEDs identify the selected

input.

Autoswitch mode controls and indicators

7

Mode button —

The Mode button is used with the Normal

button or the Auto button to select the switching mode. Mode is a
secondary function of the Input 1 button.

8

Normal button —

The Norm button is used with the Mode

button to select normal mode. Normal is a secondary function of
the Input 2 button.

9

Auto(switch) button —

The Auto button is used with the Mode

button to select autoswitching mode. Auto is a secondary
function of the Input 3 button.

10

Auto Switch LED —

When lit, the Auto Switch LED indicates

that the switcher is in autoswitch mode. The MSW automatically

switches to the highest numbered input with active SDI signals.
When unlit, the switch is in normal (manual switch) mode.

Mode selection

Turn autoswitch mode on or off as follows:

1

.

Press and hold the Mode (Input 1) button.

2a

.

To select autoswitch mode

— Press and release the Auto (Input 3)

button. The Auto Switch Mode Active LED lights.

2b

.

To select normal mode

— Press and release the Normal (Input 2)

button. The Auto Switch Mode Active LED goes off.

3

.

Release the Mode button.

Specifications

Video

Resolution ..................................... 8 or 10 bits, automatic
Operations standards .................. 143 Mb/s (4f

sc

NTSC)

177 Mb/s (4f

sc

PAL)

270 Mb/s (4:2:2) component video
360 Mb/s (4:2:2) widescreen, autoselect

Equalization and re-clocking ..... Automatic for up to -30dB of cable loss

Video input

Number/signal type ................... 4 digital component video
Connectors .................................... 4 female BNC
Minimum/maximum levels ...... 0.4V to 2.0V p-p with no offset
Impedance .................................... 75 ohms
Return loss .................................... -40dB, DC @ 10 MHz
Maximum DC offset .................... 5.0V

Video output

Number/signal type ................... 2 re-clocked SMPTE-259 serial digital component

video

Connectors .................................... 2 BNC female
Impedance .................................... 75 ohms
Return loss .................................... <-30dB @ 5 MHz
DC offset ....................................... ±5mV maximum with input at 0 offset

Sync

Standards ...................................... SMPTE-259

Control/remote — switcher

Contact closure ............................. 1 3.5 mm 5-pole captive screw connector