Outputs

2

Video output 1 —

Connect an output monitor or other VGA

device to this female 15-pin HD connector.

3

Audio output 1 —

Connect speakers to this 3.5 mm stereo jack.

4

Video output 2 —

Connect a projector or other RGBHV video

output device to these five BNC connectors.

5

Audio output 2 —

Connect speakers to this 5-pole 3.5 mm

captive screw connector. Wire the captive screw connector for
stereo output as shown in figure 2-6. Use the supplied tie-wrap
to strap the audio cable to the extended tail of the connector.

Ring

Sleeve(s)

Tip

Tip

Ring

Sleeve(s)

Tip

Tip

Unbalanced Stereo Output

Balanced Stereo Output

NO GROUND HERE.

NO GROUND HERE.

LR

Do not tin the wires!

Figure 2-6 — Audio output connections

CAUTION

Connect the sleeve to ground (Gnd). Connecting
the sleeve to a negative (-) terminal will damage the
audio output circuits.

The length of exposed (stripped) copper wires is critical.
The ideal length is 3/16” (5 mm)

.

• If the stripped section of wire is longer than 3/16”, the

exposed wires may touch, causing a short circuit
between them.

• If the stripped section of wire is shorter than 3/16”,

wires can be easily pulled out even if tightly fastened
by the captive screws.

Do not tin the stripped power supply leads before
installing the captive screw connector. Tinned wires are
not as secure in the captive screw connectors and could
be pulled out.

Remote control connections

6

Remote connector

Connect a computer or RS-232 control

module to this female 9-pin D connector to allow remote control
using the Extron Simple Instruction Set

(SIS

) or the Extron

Universal Switcher Control Program. Alternatively, connect a
contact closure device such as an Extron remote control
Architectural Adapter Plate (AAP or MAAP). See chapter 3,
“Remote Control”, for more information.

7

Tally Power connector —

This 2-pole captive screw connector

provides power to light the LEDs on Extron MMX 32 AAP
(part #70-277-01, -11, or -21) or MMX 32 MAAP (part #70-277-12,
or -22) contact closure remote control panels. Connect the 5V
and Gnd (-) 2-pole captive screw connector on the AAP or
MAAP to this connector. See chapter 3, “Remote Control”, for
more information.

Power connection

8

Power connector

An external 12V power supply is included

with the unit. Plug it into this 2-pole 3.5 mm captive screw
connector. Wire the connector as shown in figure 2-7. Use the
supplied tie-wrap to strap the power cable to the extended tail
of the connector.

Power Supply

Output Cord

SECTION A–A

Ridges

Smooth

A

A

Captive Screw

Connector

Tie Wrap

Figure 2-7 — Power connection wiring

CAUTION

Power supply voltage polarity is critical. Incorrect
voltage polarity can damage the power supply and
the MMX. Identify the power cord negative lead by
the ridges on the side of the cord (figure 2-7).

The length of exposed (stripped) copper wires is critical.
The ideal length is 5/16

" (7 mm).

• If the stripped section of wire is longer than 5/16”, the

exposed wires may touch, causing a short circuit
between them.

• If the stripped section of wire is shorter than 5/16”,

wires can be easily pulled out even if tightly fastened