Appendix a: specifications, Global water instrumentation – Xylem SIT65 SATELLITE INTERNET TELEMETRY User Manual
Page 19

Global Water Instrumentation
19
Appendix A: Specifications
Analog Inputs:
Up to 8 inputs available
10-bit resolution
Type: 0-20mA, 0-1mA, 0-500uA, 0-5VDC, 0-10VDC
Sensor Power:
5Vsw, 12Vsw, 18Vsw or 12V Continuous
Digital Inputs:
Up to 3 inputs available, counters or status
Contact closure or open collector to ground
Inputs have 20K pull-up resistor to 5VDC
Maximum accumulator count: 2047 (11-bit)
Control Outputs:
Up to 2 outputs available
Open collector output to ground
100mA each output maximum
Inductive load protected
Radio Modem:
Frequency: Transmit-150MHz, Receive-138MHz
Communication speed: 9600 Baud
Transmit power: 5 Watt
Antenna: 1 meter whip, 16 foot cable standard
Power Supply:
12VDC, 5Ahr Battery standard
Current draw: 80mA in receive mode @12VDC
5mA in power save mode
2A briefly when transmitting
Environment:
-40° to +60° Celsius, -40° to 140° Fahrenheit
100% Humidity, Non-condensing
- H-2191 (57 pages)
- H-223 (9 pages)
- H-264 (16 pages)
- H-310 (40 pages)
- H-312 (38 pages)
- H-3301 (24 pages)
- H-3342 (30 pages)
- H-335 (32 pages)
- H-339 (21 pages)
- H-340-CalKit (6 pages)
- H-340 (12 pages)
- H-340SDI (32 pages)
- H-3521 (57 pages)
- H-3531 FlashLite (76 pages)
- H-3551 (42 pages)
- H-3553 (36 pages)
- H-375 04101 WIND MONITOR-JR (18 pages)
- H-4161 (36 pages)
- H-4191 (21 pages)
- H-424MS V1.0 (25 pages)
- H-424MS V1.1 (22 pages)
- H-4271 (22 pages)
- H-4280 (34 pages)
- H-4400 (7 pages)
- H-4401 (6 pages)
- H-5223 (107 pages)
- STORM 3 UPGRADE (4 pages)
- System 5000 BASIC Manual (54 pages)
- System 5000 User Manual (136 pages)
- DH-21 (112 pages)
- BrazedPlate Heat Exchangers (4 pages)
- Heat Exchangers (8 pages)
- GL500 MULTICHANNEL DATA LOGGER (32 pages)
- 4046 ANALOG TO SDI-12 CONVERTER (7 pages)
- 4015 SDI-12 TO ANALOG CONVERTER (5 pages)
- iRIS-CAM Wastewater Security Camera (11 pages)
- SDI-12 Data Logger iRIS 220, iRIS 320, iRIS 350, iRIS 150, iRIS 300 (111 pages)
- iRIS 150 GPRS DATALOGGERS (53 pages)
- iCE3 GPRS Variant (29 pages)
- GL500-2-1 Data Logger (32 pages)
- 3101 CONDUCTIVITY CONTROLLER (11 pages)
- 3675 pH CONTROLLER (9 pages)
- 378 TEMPERATURE CONTROLLER (9 pages)
- Expert 1400 (16 pages)
- Expert 700 (8 pages)