beautypg.com

Long-term storage – Bell & Gossett P71396C Series 80-SC Spacer-Coupled Vertical In-Line Centrifugal Pump User Manual

Page 10

background image

Series 80–SC

Series 80–SC with optional ITSC

Figure 1: Proper lifting method

Long-term storage

If the unit is stored for more than 6 months, these requirements apply:

• Store in a covered and dry location.
• Store the unit free from heat, dirt, and vibrations.
• Rotate the shaft by hand several times at least every three months.

Treat bearing and machined surfaces so that they are well preserved. Refer to the drive
unit and coupling manufacturers for their long-term storage procedures.
For questions about possible long-term storage treatment services, please contact your
local sales and service representative.

Transportation and Storage

8

Series 80-SC Installation, Operation, and Maintenance Manual