Global water – Xylem CVD-2000 CELLULAR AUTODIALERS User Manual
Page 24

Global Water
800-876-1172
• globalw.com
- 24 -
X) Specifications
a) Dimensions
Power source:
9-18VDC
Current (OPERATE mode – standby):
28mA typical.
Current (OPERATE mode – dialing):
100mA max.
Activation:
1) N.C. Activation: dialer activates when an “open” is detected
2) N.O. Activation: dialer activates when a “close” is detected
3) Voltage Activation: N.C. (applied voltage: Min. +5VDC, Max. +28VDC)
N.O. (loss of continuous voltage: Min. 0VDC, Max. 0.25VDC)
Max. digits for outgoing numbers:
50
Operating temperature range:
-18 to 55 C (0 to 130 F)
Dimensions (inches):
6 x 4 x 1.5 in
Weight (ounces):
10 oz
Mounting:
Wall or Flat Surface
Case Material:
ABS
Color:
White
Warranty:
1 Year
Note: Design and specifications subject to change without notice.
XI) Dialer Accessories
a) Power Source:
AC-1: AC/DC Adaptor: Plugs into regular 110VAC outlet to provide the dialer
with the required primary power.
AC-2: AC/DC Adaptor: 12VDC/0.5A for stand alone with siren use.
PP-1: Power (Rechargeable): Provides 24 (est.) hours of backup standby power.
AC-1P: AC/DC Adaptor For Use With PP-1: Plugs into regular 110VAC outlet
to provide the dialer with the required primary power and additional input for PP-
1 interface.
IR-1: Isolation Relay: Converts alarm output voltage to N.C. to provide clean
input trigger to dialer.
b) Industrial/Residential Sensors F20:
Temperature Supervisory Switch <40 F
HTS: High Temperature Switch
LTS: Low Temperature Switch
CSS: Cold Storage Switch
WLS: Water Level Sensor
RTS: Adjustable Temperature Controller, N.O., N.C.
PLS: Power Loss Sensor (110VAC)
c) Sensors
Magnetic Contacts – Door and Window
Glass Break Detectors
Hold Up Buttons/Emergency Switches