beautypg.com

Global water – Xylem CVD-2000 CELLULAR AUTODIALERS User Manual

Page 24

background image

Global Water

800-876-1172

• globalw.com

- 24 -

X) Specifications

a) Dimensions

Power source:

9-18VDC

Current (OPERATE mode – standby):

28mA typical.

Current (OPERATE mode – dialing):

100mA max.

Activation:

1) N.C. Activation: dialer activates when an “open” is detected

2) N.O. Activation: dialer activates when a “close” is detected

3) Voltage Activation: N.C. (applied voltage: Min. +5VDC, Max. +28VDC)

N.O. (loss of continuous voltage: Min. 0VDC, Max. 0.25VDC)

Max. digits for outgoing numbers:

50

Operating temperature range:

-18 to 55 C (0 to 130 F)

Dimensions (inches):

6 x 4 x 1.5 in

Weight (ounces):

10 oz

Mounting:

Wall or Flat Surface

Case Material:

ABS

Color:

White

Warranty:

1 Year

Note: Design and specifications subject to change without notice.


XI) Dialer Accessories

a) Power Source:

AC-1: AC/DC Adaptor: Plugs into regular 110VAC outlet to provide the dialer
with the required primary power.
AC-2: AC/DC Adaptor: 12VDC/0.5A for stand alone with siren use.
PP-1: Power (Rechargeable): Provides 24 (est.) hours of backup standby power.
AC-1P: AC/DC Adaptor For Use With PP-1: Plugs into regular 110VAC outlet
to provide the dialer with the required primary power and additional input for PP-
1 interface.
IR-1: Isolation Relay: Converts alarm output voltage to N.C. to provide clean
input trigger to dialer.

b) Industrial/Residential Sensors F20:

Temperature Supervisory Switch <40 F
HTS: High Temperature Switch
LTS: Low Temperature Switch
CSS: Cold Storage Switch
WLS: Water Level Sensor
RTS: Adjustable Temperature Controller, N.O., N.C.
PLS: Power Loss Sensor (110VAC)

c) Sensors

Magnetic Contacts – Door and Window
Glass Break Detectors
Hold Up Buttons/Emergency Switches