Xylem IMDWT R02 Model DWT Deep Well Turbine Pumps User Manual
Page 23
![background image](/manuals/310470/23/background.png)
23
TroUBLESHooTING
TroUBLE
ProBABLE CAUSE
rEMEdY
6. Pump takes too much
A. Damaged impeller
Inspect, replace if damaged.
power
B. Foreign object lodged between Remove object as required.
impeller and bowl
C. Specific gravity higher than
Test liquid for viscosity and
pump designed for
specific gravity.
D. Viscosity too high, partial
Check for both. They can cause
freezing of pumpage
drag on impeller.
E. Defective bearing
Replace bearing, check shaft or
shaft sleeve for scoring.
F. Packing is too tight
Release gland pressure.
Retighten. (See page 18.) Keep
leakage flowing. If no leakage,
check packing, sleeve or shaft.
7. Pump is too noisy
A. Cavitation
Same as Item 3-B.
B. Bent shaft
Straighten as required. See
Page 11 for runout limits.
C. Rotating parts binding, loose
Replace as required.
or broken.
D. Bearings are worn out
Replace bearings.
E. Resonance
Check piping strain, consult factory.
8. Excessive vibrations
A. Coupling misalignment, bent Determine cause utilizing shaft
impeller unbalance, worn
vibration frequency analyzer
bearings, cavitation, piping
and/or pump disassemble.
strain and/or resonance
Complex problem may require
factory service assistance.
B. Motor or gear driveshaft end
See Installation of Hollow Shaft
play maladjustment
Driver (VHS), Page 15.
C. Bent shaft
Straighten as required. See
Page 11 for runout limits.
D. Crooked well.
Survey the well and consult factory.
9. Pump leaks excessively
A. Defective packing
Replace worn packing.
at stuffing box
B. Wrong type of packing
Replace packing not properly
installed or run-in. Replace
improper packing with correct
grade for liquid being pumped.
10. Stuffing box is
A. Packing is too tight
See item 6-F.
overheating
B. Packing is not lubricated
Release gland pressure and
replace all packing if burnt or
damaged. Re-grease packing
as required.
C. Wrong grade of packing
Consult factory.
D. Stuffing box improperly packed Repack stuffing box.
11. Packing wears too fast
A. Shaft or shaft sleeve worn
Pull pump and remachine, or
replace shaft and/or sleeve.
B. Insufficient or no lubrication
Repack and make sure packing
is loose enough to allow some
leakage.
C. Improperly packed
Repack properly, make sure all
old packing is removed and
stuffing box is clean.
D. Wrong grade of packing
Consult factory.