beautypg.com

AVSL 160.465 FH-1500 User Manual

Page 4

background image

160.465UK User Manual

Setting up

Make sure that none of the remote timer control buttons are pressed in at startup

The FH-1500 has an angle adjustable aperture. Adjust this to direct the haze output before switching on.

Switch the mains power on (7)

Heat up time for haze effect is usually between 7-8 minutes.

During prolonged use, periodically check that the fluid level is not empty

Switch off when not in use. Unplug from mains if not in use for long periods

Warning: There will be hot surfaces on the housing even after the machine is switched off

Remote timer control

When the machine is ready to operate, the ready light (5) on the remote

timer control will illuminate.

You may now press the Manual (3) button for haze on demand – releasing button stops the haze effect

When the ready indicator is off, the FH-1500 needs time to re-heat and will not produce haze effect

For constant haze effect, use the latching Continuous (2) button and the Continuous LED (6) will light

The density of haze effect can be varied by adjusting the rotary Output control (7)

Pressing the Timer button (1) will activate the hands-free timer function and the timer LED (4) will light

The Interval control (8) adjusts the time between haze effect output in each timer cycle

The Duration control (9) adjusts the length of time that haze is produced in each timer cycle

Turn down the rotary FAN SPEED control on the rear panel for a more dense fog effect

Wireless remote control

Haze can also be controlled manually by the wireless remote control

The key fob remote is powered by a button cell, replace this with similar type if discharged

Extend the antenna on the key fob, slide down the front cover

Press one of the key fob buttons to produce haze


DMX operation

The FH-1500 can be operated by a single channel of DMX512 control.
Set this address via the rear panel DIP switches as shown above
A value of 0 will give no haze output. A value between 1 and 255 will give full haze output.

1.

Timer button (latching) - activates the timer control

2.

Continuous button (latching) – overrides timer control for constant haze

3 . Manual button (non-latching) – overrides timer control for haze on demand

4.

Timer indicator – illuminated when timer function is active

5.

Ready indicator – illuminated when heated up ready to produce haze

6.

Continuous indicator – illuminated when continuous function is active

7.

Output control – adjusts the amount and density of haze effect

8.

Interval control – adjusts the interval between haze output on timer control

9.

Duration control – adjusts the time length of haze output on timer control