WARNING
:
take into consideration the following information and restrictions in order to avoid damag-
ing the device and to ensure a long service life and failure-free operation:
• Performance of the device in nighttime conditions depends on the level of ambient light in
the environment. Some light (moonlight, starlight, etc.) is required for the device to provide an
image.
• Ambient light level is reduced by the presence of clouds, shade, or objects that block natural
light (buildings, trees, etc.).
• The device loses its effectiveness when operated in shadowed areas.
• The effectiveness of the device is adversely affected by weather conditions such as rain,
snow, sleet, or fog, and environmental conditions such as smoke or dust.
• The device resolution level is reduced in environments with very low light sources. The vis-
ibility will degrade significantly under starlit conditions, particularly in low contrast environ-
ments such as deserts, large areas of uniform vegetation, etc.
• The device is equipped with a protection system that will automatically disable the image
intensifier tube when the illuminance level stays above 40 lux for over 10 seconds.
BATTERY INSTALLATION
1) Unscrew the battery compartment cap on the front side of the binoculars’ body.
2) Insert the CR123A battery into the battery compartment in accordance with polarity markings.
3) Screw the cap into place.
TRIPOD INSTALLATION
The Dark Strider can be connected to a tripod. To mount the tripod with the Dark Strider device, screw
the tripod into the 1/4’’ threaded socket located on the tripod adapter of the Dark Strider.
NOTE:
The unit may be badly damaged if the tripod collapses or falls over. Remove the unit from the
tripod if it is not within your reach.
3. OPERATION INSTRUCTIONS
CONTROLS
The Dark Strider is designed to meet the needs and requirements of various users. Each user can indi-
vidually set the unit to the most effective and desirable position with the help of the controls. The Dark
Strider unit controls and indicators are shown and detailed further, below:
pWr Button. This controls the power supply to the unit. Use this button to turn the unit on and off.
ir Button. This button controls the power supply to the built-in infrared illuminator. Use this button to
turn the IR illuminator on and off.
diopter adjustment. This control focuses the eyepieces. Use it to get the clearest image possible on
the IIT screen.
ir illuminator focus adjustment. This control focuses the IR beam. To adjust the IR beam, rotate the