beautypg.com

5 checking the drives for data consistency, Using the check consistency command – Asus Z8NA-D6 User Manual

Page 121

background image

ASUS Z8NA-D6 Series

5-19

5.2.5

Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected virtual

drive. The utility can automatically detect and/or detect and correct any differences

in data redundancy depending on the selected option in the

Objects > Adapter

menu.

The

Check Consistency command is available only for virtual drives included

in a RAID 1 or RAID 10 set.

Using the Check Consistency Command

To check data consistency using the

Check Consistency command

1. From the

Management Menu, select Check Consistency, and then press

.

2. The screen displays the available RAID set(s) and prompts you to select

the virtual drive to check. Press to select the virtual drive from the

Virtual Drive sub-menu, and then press .

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

CC Of VD(s)

LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008

BIOS Version A.08.09161344R

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

Select VD

Virtual Drive(s) Configured

LD RAID Size #Stripes StripSz Status

0 10 154494MB 4 64 KB ONLINE

Virtual Drives

Virtual Drive 0

LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008

BIOS Version A.08.09161344R

SPACE-(De)Select, F10-Check Consistency

This manual is related to the following products: