Troubleshooting – AEG S53400CSS0 User Manual
Page 31
• when all the ice has melted, clean and
wipe the cabinet dry, then put the
drainage channel back in place.
• switch on the cabinet and replace the
frozen foodstuff.
It is recommended to operate the ap-
pliance at the highest position of the
thermostatic control for some hours
so that it can reach the sufficient stor-
ing temperature as soon as possible.
Never use sharp metal tools to
scrape off frost from the evapo-
rator as you could damage it. Do
not use a mechanical device or
any artificial means to speed up
the thawing process other than
those recommended by the
manufacturer. A temperature rise
of the frozen food packs, during
defrosting, may shorten their
safe storage life.
7. TROUBLESHOOTING
CAUTION!
Before troubleshooting, discon-
nect the power supply.
Only a qualified electrician or
competent person must do the
troubleshooting that is not in this
manual.
There are some sounds during
normal use (compressor, refriger-
ant circulation).
Problem
Possible cause
Solution
The appliance is
noisy.
The appliance is not sup-
ported properly.
Check if the appliance
stands stable (all the four
feet should be on the
floor).
The compressor op-
erates continually.
The Temperature regula-
tor may be set incorrectly.
Set a warmer temperature.
The door is not closed
correctly.
Refer to "Closing the
door".
The door has been
opened too frequently.
Do not keep the door
open longer than necessa-
ry.
The product temperature
is too high.
Let the product tempera-
ture decrease to room
temperature before stor-
age.
The room temperature is
too high.
Decrease the room tem-
perature.
Water flows on the
rear plate of the re-
frigerator.
During the automatic de-
frosting process, frost de-
frosts on the rear plate.
This is correct.
Water flows into the
refrigerator.
The water outlet is clog-
ged.
Clean the water outlet.
Products prevent that wa-
ter flows into the water
collector.
Make sure that products
do not touch the rear
plate.
ENGLISH
31