7 depth of cure – GC EUROPE G-aenial User Manual
Page 22

22
G-ænial Anterior & Posterior Technical Manual
6.7 Depth of cure
the depth of cure of G-ænial was determined with a scraping technique described in the iSO
4049:2000 specifications.
table 5: G-ænial anterior: irradiation time and effective depth of cure
irradiation time
Plasma arc (2000 mW/cm²)
Gc G-light (1200 mW/cm²)
halogen / leD (700 mW/cm²)
Shade
3 sec.
10 sec.
20 sec.
6 sec.
20 sec.
40 sec.
te, ie, Je, Se, cVe
3.0 mm
3.5 mm
a1, a2, B1, B2, XBW, BW, ae
2.5 mm
3.0 mm
a3, B3
2.0 mm
3.0 mm
a3.5, a4, c3, aO2, aO3, aO4, cV, cVD
1.5 mm
2.5 mm
table 6: G-ænial Posterior: irradiation time and effective depth of cure
irradiation time
Plasma arc (2000 mW/cm²)
Gc G-light (1200 mW/cm²)
halogen / leD (700 mW/cm²)
Shade
3 sec.
10 sec.
20 sec.
6 sec.
20 sec.
40 sec.
P-a1, P-a2, P-Je, P-ie
2.5 mm
3.0 mm
P-a3, P-a3.5
2.0 mm
3.0 mm
Filtek Z250 and Filtek Supreme Xte are trademarks of 3m/espe. tetric evoceram is a trademark of Vivadent. esthetX hD and
ceramX mono are trademarks of Dentsply. clearfil majesty is a trademark of Kuraray. Venus is a trademark of heraeus.
estelite ∑ Quick is a trademark of tokuyama.