18
0,00
0,50
1,00
1,50
2,00
2,50
3,00
3,50
Filtek Z250
EsthetX HD
Herculite Ultra
Estelite ∑ Quick
Tetric EvoCeram
Clearfil Majesty Esthetic
Venus
CeramX mono
G-ænial P
G-ænial A
G-ænial Anterior & Posterior Technical Manual
6.2 Shrinkage
Volumetric shrinkage (%)
Pre- and post-curing composite resin densities were measured and the polymerization shrinkage
calculated accordingly
Figure 27: Volumetric shrinkage of various composites Source: Gc corporation
Shrinkage stress
Figure 28: Shrinkage stress test with universal testing machine
the sample was light-cured for 40 seconds from the underside using a G-light 11mm fiber rod,
then light-cured for 20 seconds from above. the setting shrinkage stress was measured for 20
minutes and the highest figure reached was recorded as the shrinkage stress.
Figure 30: Shrinkage stress of various composites Source: Gc corporation
the volumetric shrinkage was measured
following iSO Draft Date: 2007-07-10
(Dentistry - Polymerization shrinkage of
filling materials) specifications.
this study demonstrated that
the volumetric shrinkage of
G-ænial is within the average
of the tested composites.
Volumetric shrinkage (%)