PART 1 – GENERAL

1.1 RELATED

DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply

to this section

1.2 SUMMARY

A. This section includes the following:

1. Common standard floor mounted chairs as detailed in Part 2 of these specifications.

1.3 SUBMITTALS

A. Product data for each type of product specified. Include installation methods.

B.

Shop drawings, prepared for architectural drawings and from field dimensions, showing the seating layout,
seat numbering sequence, chair sizes, and aisle widths. Also show a section view with profile dimensions
of the seating and back-to-back dimensions.

C.

Samples for initial selection purposes in the form of manufacturer’s color charts or samples of materials
showing the full range of standard colors, finishes, and patterns.

1.

Fabric

2.

Metal

Finishes

3.

Wood

Finishes

D.

Statement signed by the theater seating manufacturer confirming that the products submitted comply with
the specified requirements.

1.4 QUALITY

ASSURANCE

A. Provide installer’s qualifications confirming the installer is qualified to install the manufacturer’s chairs

B. Provide seating that complies with California Technical Bulletin 117.

C. Obtain each type of seating, including accessories and mounting components, from a single manufacturer.

D.

Design and install seating with end standards aligning from first to last row and with backs and seats varied
in width to optimize sightlines. Comply with ADA rules and regulations.

1.5 PROJECT

CONDITIONS

A. Environmental Conditions: Do not install seating until space is enclosed and weatherproof, wet work in

space is complete and dry, installation of finishes including painting is complete, and ceilings are complete.
Do not install seating until ambient temperature and humidity conditions are continuously maintained at
final occupancy values.

1.6 DELIVERY, STORAGE, AND HANDLING

A. Deliver seating in manufacturer’s unopened cartons clearly labeled with manufacturer’s name and

contents.

B. Handle seating in manner to prevent damage.

1.7 EXTRA

MATERIALS

A. Furnish from the same production run as the materials installed. Package materials with protective

covering and identify with labels describing contents.

1. Seat and back covers to be furnished in a quantity equal to 5 percent of the amount of chairs

installed.

PART 2 – PRODUCTS

2.1 SEATING

A. Provide from Theatre Solutions, Inc., 121 Park Avenue, Quakertown, PA 18951, the Prima “C3-W” model

as follows:

1. Basic floor mounted chair.

2. Fully upholstered seat and back.