Aqua-Pure NWS200 User Manual
Page 17

5-1
SECTION 5: SPECIFICATION AND OPERATING DATA
Time Clock Initiated
Meter Initiated
ITEM
NWS100
NWS150
NWS200
NWS100M
NWS150M
NWS200M
Nominal Media Volume, cu. ft. (cu mtr)
1.0 (0.03)
1.5 (0.05)
2.0 (0.06)
1.0 (0.03)
1.5 (0.05)
2.0 (0.06)
Salt Dosage, lbs (kg):
Factory Setting (1)
Maximum Setting
6.0 (2.7)
15.0 (6.8)
9.0 (4.1)
24.0 (11)
12.0 (5.4)
24.0 (11)
6.0 (2.7)
15.0 (6.8)
9.0 (4.1)
24.0 (11)
12.0 (5.4)
24.0 (11)
Nominal Softening Capacity, Grains (2)
At factory salt setting
At maximum salt setting
18,600
30,000
27,900
45,000
37,200
54,000
18,600
30,000
27,900
45,000
37,200
54,000
Operating Flow Rates, gpm (lpm) (3)
Service (10 minutes or less)
7.0 (27)
8.0 (30)
8.5 (32)
7.0 (27)
8.0 (30)
8.5 (32)
Pressure Loss @ Service Flow Rate, psi (kPa)
15.0 (103)
15.0 (103)
15.0 (103)
15.0 (103)
15.0 (103)
15.0 (103)
Regeneration Flow Rates, gpm (lpm)
Backwash (4)
Brine/Rinse
Rapid Rinse
Brine Refi ll
Approx Water Used
1.5 (5.7)
0.33 (1.25)
1.5 (5.7)
0.5 (1.9)
65 (246)
2.4 (9.1)
0.33 (1.25)
2.4 (9.1)
0.5 (1.9)
90 (341)
2.4 (9.1)
0.33 (1.25)
2.4 (9.1)
0.5 (1.9)
91 (344)
1.5 (5.7)
0.33 (1.25)
1.5 (5.7)
0.5 (1.9)
64 (242)
2.4 (9.1)
0.33 (1.25)
2.4 (9.1)
0.5 (1.9)
90 (341)
2.4 (9.1)
0.33 (1.25)
2.4 (9.1)
0.5 (1.9)
91 (344)
Inlet/Outlet Pipe Size, Inches (cm)
1.0 (2.5)
1.0 (2.5)
1.0 (2.5)
1.0 (2.5)
1.0 (2.5)
1.0 (2.5)
Media Tank Depth & Height w/Control Valve, Inches (cm)
8x44
(20x112)
10x44
(25x112)
10x54
(25x137)
8x44
(20x112)
10x44
(25x112)
10x54
(25x137)
Overall Depth & Height
w/ Control Valve, Inches (cm)
15x51
(38x130)
15x51
(38x130)
15x61
(38x155
17x51
(43x130)
17x51
(43x130)
17x61
(43x155)
Brine Tank, W x D x H, Inches (cm)
15x15x34
(38x38x86)
15x15x34
(38x38x86)
15x15x34
(38x38x86)
15x15x34
(38x38x86)
15x15x34
(38x38x86
15x15x34
(38x38x86)
Approx. Salt Storage, lbs. (kg)
160 (73)
160 (73)
160 (73)
160 (73)
160 (73)
160 (73)
Approximate Shipping Weight, lbs. (kg)
100 (45.4)
125 (56.7)
160 (72.6)
101 (45.8)
126 (57.1)
161 (73)
Maximum operating temperature 110°F (43.3°C); Electrical requirements 110V/60Hz (220V/50Hz); Operating pressure 20-125 psi. Most types of water
softener salt may be used (See Maintenance). 3M Purifi cation Inc. does not allow the use of block type water softener salt. Specifi cations subject to change
without notice.
NOTES:
1)
Meter Initiated Water Softeners: Dial settings based on this capacity. Consult dealer before changing salt dosage.
2)
Actual capacity may vary substantially depending on water analysis and operating conditions.
3) For satisfactory performance indicated fl ow rates and duration should not be exceeded. Flow rates specifi ed are adequate for normal residential applica-
tions. Do not use Service Flow Rate when sizing commercial applications or if treated water is to supply a geothermal heat pump, swimming pool, etc.
(contact dealer before selecting equipment).
4)
For system to operate properly, pumping rate of well pump MUST be suffi cient to backwash unit at rate specifi ed.