Installation, operation and maintenance manual, Parts list item no. description part no – Aqua-Pure AP-RO5500 User Manual
Page 16

Installation, Operation and Maintenance Manual
Long Term Non-Use
If the RO fi ltration system is left unused for long periods (>30 days), follow this procedure:
A) Open faucet to drain tank and turn off feedwater valve. Wait fi ve minutes for RO assembly to depressurize.
B) Remove all cartridges. Turn cartridges upside down in sink or container to drain out as much water as
possible.
C) When RO fi ltration system is ready to be put into service, reinstall cartridges in the RO assembly
heads and sanitize storage tank as described in Section 4. The RO assembly can also be sanitized at
this time, if desired.
D) Follow start up procedure outlined in Section 4.
18. Parts List
Item No.
Description
Part No.
1
RO Membrane Module
56084-01
2
Replacement Cartridges
(Pre and Post fi lters # AP5527)
55981-01
3
Shut Off Valve
60-90119
4
SFC Tubing
52-318212
5
Storage Tank (not shown)
56-18125
2
4
1
3