B.3.28. at+btrssi,n, B.3.29. at&v, B.3.30. atsnn – SENA Parani-SD200L User Manual
Page 37: B.3.31. atsnn=mm

37
Parameters
n=0: Inactivate (Default)
n=1: Activate
Description
During no data transmission, Parani-SD200L can be in low power mode to save the power.
It takes a few seconds to wake the Parani-SD200L out of low power mode.
B.3.28. AT+BTRSSI,n
SD Response
OK
0,255,0,0(repeatedly)
Purpose
Test signal strength
Parameters
n=0: Stop signal strength test
n=1: Start signal strength test
Description
When Bluetooth connection is established, you can use this command in Standby status.
The signal strength will be displayed repeatedly in order of Status, LinkQuality, Status,
RSSI. If the LinkQuality is close to 255 and RSSI is close to 0, the signal strength is in good
standing.
Example
+++
AT+BTRSSI,1
OK
0,255,0,0
B.3.29. AT&V
SD Response
S0:m0;S1:m1; …Sn:mn
OK
Purpose
Display all the S-registers
Description
All parameters are stored at S-register in flash memory. These values are sustained until a
hardware reset.
Reference
ATS
B.3.30. ATSnn?
SD Response
value
OK
Purpose
Display a given S-register
Parameters
nn= Address of S-register
Description
A specific S-register will be displayed.
Reference
AT&V
B.3.31. ATSnn=mm
SD Response
OK
Purpose
Change S-register value