B.3.29. at+btlpm,n, B.3.30. at&v, B.3.31. atsnn – SENA Parani-ESD100-110-200-210 User Manual
Page 45: B.3.32. atsnn=mm

45
Description
Parani-ESD can have a user friendly name for easy identification. The name allows up to
30 alpha-numeric characters.
Reference
AT+BTINFO?, AT+BTINQ?
Example
AT+BTNAME=”My-Parani-ESD”
B.3.29. AT+BTLPM,n
Response
OK
Purpose
Set low power mode
Parameters
n=0: Inactivate (Default)
n=1: Activate
Description
During no data transmission, Parani-ESD can be in low power mode to save the power. It
takes a few seconds to wake the Parani-ESD out of low power mode.
B.3.30. AT&V
Response
S0:m0;S1:m1; …Sn:mn
OK
Purpose
Display all the S-register
Description
All parameters are stored at S-register in flash memory. These values are sustained until
hardware reset.
Reference
ATS
B.3.31. ATSnn?
Response
value
OK
Purpose
Display a given S-register
Parameters
nn= Address of S-register
Description
A specific S-register will be displayed.
Reference
AT&V
B.3.32. ATSnn=mm
Response
OK
Purpose
Change S-register value
Parameters
nn= Address of S-register
mm= New value of S-register
Description
Some S-registers are optimized for the overall performance and protected and cannot be
changed. When users try to change these S-registers, response is ‘ERROR’.
For details of S-register, refer Appendix. B.
Reference
AT&V
Example
ATS10=0