beautypg.com

Factory Direct Hardware Toto TEU1LN12#CP User Manual

Variation & specification, Set-up drawing, Installation precautions

background image

Variation & Specification

INSTALLATION MANUAL

Set-up Drawing

Model number

Figure

Approx. 1.6

gallon (6L)

Approx. 3.5

gallon (13L)

c

Connection of the

water supply pipe

Supply water

pressure

Shutoff pressure

Discharge quantity

per flush at 28 PSI

(196kPa)

(Factory set)

7 PSI (48kPa)

1"NPT

Model number

Detection time

Urinal Flush Valve

6 seconds or more

Detection time

6 seconds or more

Approx. 1.0 gallon

(3.8L)

Ambient temperature

Connection of the

water supply pipe

Supply water

pressure

Shutoff pressure

Discharge quantity

per flush at 28 PSI

(196kPa)

(Factory set)

Minimum required water pressure: 15 PSI (103kPa)

(flowing)

Maximum water pressure: 125 PSI (862kPa)

7 PSI (48kPa)

32-104˚F (0-40˚C)

Water temperature 34-104˚F (1-40˚C)

3/4"NPT

Check local codes

TET1GN32#CP

Installation Precautions

Toilet Flush Valve

1. Prior to Installation

Prior to Installing your TOTO

®`

s EcoPower

®

Flush Valve, install the items

listed bellow:
· Closet fixture/Urinal fixture

· Drain line

· Water supply line

The supply piping to these devices shall be securely anchored to the

building structure to prevent the installed device from having unnecessary

movement when operated by the user. Care shall be exercised when

installing the device to prevent marring the exposed surface.

2. Important

All plumbing is to be installed in accordance with applicable codes

and regulations. Water supply lines must be sized to provide an

adequate volume of water for each fixture.

Flush all waterlines prior to operation.

The minimum pressure required to the valve is determined by the type

of fixture selected. Consult fixture manufacturer for pressure requirement.

Do not use toothed tools to install or service the valve.

Be sure to install TOTO

®`

s EcoPower

®

Flush Valve so that the control stop

is situated no more than 11-1/2"(292mm) above the top of the bowl or
the urinal. Refer to local codes for special requirements.Except for

TET6GN#CP,TEW6GN#CP and TET6LN#CP, make sure that the control

stop is installed 27" adove the top of the bowl for proper valve function.

3. Use care not to damage the surface of the infrared sensor.

4. For Toilet Flush Valve

The toilet sensor valve may not function if toilet seat and/or lid cover are

left upright as it may block the sensor.

5. For Urinal Flush Valve

The Urinal Flush Valve is designed to be used with a washout urinal

for optimum performance. However, a siphon jet urinal may also be

substituted. Blowout urinals are not recommended.

6. The detection range of the infrared sensor is shown in the figure above.

Do not install a handrail or any other object within the detection zone

of the sensor, as any object blocking the sensor may cause the valve to

malfunction. Additionally, to avoid the possibility of valve malfunction, do not

install the flush valve in a location where the sensor faces a mirror,

stainless steel wall, other highly reflective surface or another infrared sensor.

To be continued on the back

Figure

Note

Components

1. Required tools

Adjustable wrench, Phillips and slotted screwdrivers.

2. Inspection

Unpack the flush valve and carefully make sure the cover, main unit and

all other parts are included and intact before starting installation of the

product.

Item

Figure

Description

Q’ty

A

Valve Body

assembly

1

B

Top cover

assembly

1

C

D

Screw

2

F

Back-up

battery Pack

1

G

Tool

(Allen wrench) 1

H

Notice Label

1

Owner's

Manual

1

1

Toilet Flush Valve

For TET1GN32#CP, TEW1GN32#CP, TET6GN32#CP,

I

Vacuum

breaker tube

(with spud

joint)

1

J

Control stop

1

K

Sweat

solder kit

(Escutcheon,

covering tube,

adapter)

1

E

TOTO

For the best results, be sure to read the following installation instructions and use the product only as described in this manual.

Ambient temperature

32-104˚F (0-40˚C)

Water temperature 34-104˚F (1-40˚C)

Dimension of Cover

7-3/4" (H) 4-1/2"(W) 3-1/8"(D)

(198mm(H) 115mm(W) 80mm(D))

Dimension of Cover

7-3/4" (H) 4-1/2"(W) 3-1/8"(D)

(198mm(H) 115mm(W) 80mm(D))

Installation

Manual

(this manual)

03585T3R

11-1/2"

(292mm)

1-1/2"

NPSM

Min.2-1/4"(57mm)

3/4"NPT

inlet supply

EcoPower

®

Flush Valve

4-3/4" 1/2"

(120 13mm)

4-3/4" 1/2"

(120 13mm)

Min.2-1/4"

(57mm)

1"NPT

inlet supply

11-1/2"

(292mm)

Check local codes

1-1/2"

NPSM

4-3/4" 1/2"

(120 13mm)

Min.2-1/4"

(57mm)

1"NPT

inlet supply

27"

(686mm)

Check local codes

1-1/2"

NPSM

Detection zone

The detection zone is self-adjusting and is equipped with a

3-second flush delay. (No flush delay for Urinal flush valve)

The detection zone may differ according to the color of the

user’s clothes.

When a user wears black clothes, the detection zone may

become smaller and the valve may not flush.

“AVOID”

DO NOT place the Infrared

stainless steel wall, or other

highly reflective surface.

Mirror, Stainless steel wall or

other highly reflective surface.

Infrared sensor of the

another automatic

flush valve.

Infrared sensor of the

automatic flush valve.

“AVOID”

DO NOT place the Infrared

sensor of one urinal so that sensor in front of a mirror,

it is in line with the sensor

of another automatic flush

valve sensor.

Infrared sensor of the

automatic flush valve.

L

Max19-11/16"

(Max 500 mm)

Max31-1/2"

(Max 800 mm)

15

L

Max21-1/4"

(Max 550 mm)

Max33-1/2"

(Max 850 mm)

20

TET1LN(32)#CP

TET6LN(32)#CP

TEU1GN(12,22)#CP

TET1GN(32)#CP

TET6GN(32)#CP

TEU1LN(12,22)#CP

TEW1GN(32)#CP

TEW6GN(32)#CP

Approx. 1.28

gallon (4.8L)

Approx. 0.5 gallon

(1.9L)

Minimum
(Flowing)

Maximum

15 PSI (103kPa)

125 PSI (862kPa)

35 PSI (241kPa)

TET6GN(32)#CP

TEW6GN(32)#CP

TET1LN(32)#CP

TEU1LN(12,22)#CP

TET1GN(32)#CP

TEU1GN(12,22)#CP

TEW1GN(32)#CP

TEW1LN(32)#CP

TEW1GN32#CP

TET1LN32#CP

TET6GN32#CP

TEW6GN32#CP

TET6LN32#CP

TEU1GN(12,22)#CP

TEU1LN(12,22)#CP

TEW6GN32#CP, TEU1GN(12, 22)#CP, TET1LN32#CP,

TET6LN32#CP AND TEU1LN(12, 22) #CP

Table of contents