User Instructions

Pivot the lever upward to turn the water on, down to turn it off. Pivot the handle left

to obtain warmer water, to the right to obtain cooler water.

When the unit is turned on, the water will come from the tub filler. Pull the diverter

knob to obtain water from the handshower When the water is turned off, the

diverter will automatically reset to the tub filler position.

The handshower uses the Rubit!™ self-cleaning system. The

spray channels are lined with a material that resists scale

buildup. If scale buildup is noticed in the spray channels, turn

the water on lightly and rub across the channels with a finger

or a sponge to dislodge them.

The check valve located in the handshower outlet should be

removed and checked yearly.

Reset the High Temperature

Limit Stop (Optional)

Use a 4 mm allen wrench to push the

gray rubber screw cover through the

hole in the handle. Loosen the handle

screw 4 complete turns. Pull the

handle off. Retrieve the screw cover.

Remove the nut cover and the handle

screw.

Center the cartridge stem.