12 upper and lower rotary travel limit switch – R&M Materials Handling ELECTRIC CHAIN HOISTS LoadMate Chain Hoist LM 16-20-25 User Manual
Page 36
LM16-20-25 I&M MANUAL/EN/11.30.2010
36/73
This document and the information contained herein, is the exclusive property of R&M Materials Handling, Inc., and represents a non-public, confidential and proprietary trade secret that
may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of R&M Materials Handling, Inc.
Copyright © (2010) R&M Materials Handling, Inc. All rights reserved.
6.12 Upper and Lower Rotary Travel Limit Switch
The rotary limit switch is adjustable and provides over-travel protection for the upper and lower limits of hoist
travel. The limit switch is connected to the control circuit.
Note: Rotary limit switch assembly cannot be added to a Hoist. The Hoist must have the
rotary limit switch assembly provided at time of initial production.
Adjustment
The position of the air-gap between the two discs (red – gray) determines the stopping place. This position
can be found by gently turning the two discs. The length of air gap determines length of reset play in
opposite direction.
To reset the rotary limit once it has tripped, the load block assembly must travel approximately 11”
[27cm] in opposite direction.