Turning the Meter On and Off

Press the Power button for approximately 3 seconds to turn

the meter on.

To turn the meter off, press the Power button until the

display goes blank.


Making Measurements
All measurements described in this manual use the Red test
lead for positive (+) polarity and Black test lead for Ground
reference (-) unless otherwise specified

Auto-Select Mode

The Auto-Select feature automatically selects measurement

function of V dc, V ac, or resistance based on the input via
the test leads.

With no input, the meter displays Auto when it is ready.

With no voltage signal but a resistance below 40MΩis

present, the meter displays the resistance value, this
function is auto-ranging

When a signal above the threshold of 0.6 V dc or 1.6V ac

up to the rated 600 V is present, the meter displays the
appropriate voltage value in dc or ac, whichever larger in
peak magnitude, this function is auto-ranging

The Auto-Select test With High input impedance: 10MΩ

which ensure the Best accuracy.


Overload-Alert Feature
When above rated 600 V is present, the meter displays OL
with a warning beep tone. Disconnect the test leads from the
signal immediately to avoid hazards.