Display back light
The illumination button of the display can be switched on or off, User
can trigger the function when he/she is in darkness situation. The value
is clearly visible on the LCD
Distance unit setting for instrument
Click and hold the button longer to change to the next type of unit,
m, ft. in, ft+/in then to continue click the button for the next unit
selection.
MEASURING
Single distance measurement
Press to activate the laser. Press again to trigger the distance
measurement. The measured value is displayed immediately.
Continuous Measurement (Tracking)
Maximum and Minimum Measurement
See fig.E
Fig.E
The continuous measurement function (tracking) is used
for the transferring of measurements, e.g., from
construction plans. In continuous measurement mode,
the measuring tool can be moved close to the target,
whereby the measured value is updated approx. every
0.5 seconds. The corresponding dynamically maximum
and minimum values are displayed in the first and
second line.
As an example, the user can move from a wall to the required distance,
while the actual distance can be read continuously. For continuous
measurement, push button
until the indicator for continuous
measurement appears in the display. And press it again or
to stop
the function. The function is terminated after continuous measurement
for 5 minutes.