OPERATING INSTRUCTIONS
1
2
3
4
5
6
Tone
detector
F male
to RCA
female
RCA cable
F male
to RCA
female
F double
connector
NT-302
Common use for cable testing instruction:
1. Take the NT-30 mini pocket tester, then unscrew the “tone”
detector which is conveniently stored in the base section
. Put a double female “F” connectors into the top of NT-30
push-on fitting port, and put another type of connector
which one end matching the desired test cable plug.
3. Connect the connector with desired test cable properly
4. Add a type of connector which matches both ends of de-
sired test cable end plug and the “tone” detector
5. Put the “tone” detector to the matching connector
6. When the desired test cable short circuit was found, the
LED lights up and the tone will sound
Cable in an MDU testing instruction:
1. Take the NT-30 Mini Pocket Tester, then unscrew the
“tone” detector which is conveniently stored in the base
section
2. The main section of NT-302 has a male “F” push-on fitting.
Attach this push-on fitting to a female “F” port on an apart-
ment wall plate.
3. Tough the “tone” detector to each one of the cables at the
remote location. When the correct cable from the transmit-
ter location is found, the tone will sound.
Note: To replace the battery, unscrew the battery chamber
access cap above the tone detector. Battery type: 3A-1V