beautypg.com

Typical operating characteristics (continued) – Rainbow Electronics MAX1847 User Manual

Page 7

background image

MAX1846/MAX1847

High-Efficiency, Current-Mode,

Inverting PWM Controller

_______________________________________________________________________________________

7

I

L

0

5V/div

1A/div

5V/div

V

OUT

ENTERING SHUTDOWN

MAX1846/7 toc16

APPLICATION CIRCUIT B

1ms/div

SHDN

I

L

LX

1A/div

10V/div

100mV/div

V

OUT

HEAVY-LOAD SWITCHING

WAVEFORM

MAX1846/7 toc17

APPLICATION CIRCUIT B

1

µs/div

I

LOAD

= 600mA

I

L

LX

1A/div

10V/div

100mV/div

V

OUT

LIGHT-LOAD SWITCHING

WAVEFORM

MAX1846/7 toc18

APPLICATION CIRCUIT B

1

µs/div

I

LOAD

= 50mA

I

L

1A/div

500mV/div

I

LOAD

V

OUT

LOAD-TRANSIENT RESPONSE

MAX1846/7 toc19

APPLICATION CIRCUIT B

2ms/div

I

LOAD

= 10mA to 400mA

I

L

500mA/div

200mV/div

I

LOAD

V

OUT

LOAD-TRANSIENT RESPONSE

MAX1846/7 toc20

APPLICATION CIRCUIT C

400

µs/div

I

LOAD

= 4mA to 100mA

Typical Operating Characteristics (continued)

(Circuit references are from Table 1 in the Main Application Circuits section, C

VL

= 0.47µF, C

REF

= 0.1µF, T

A

= +25°C, unless otherwise

noted.)