Functional Description

(Continued)

12.7 Interrupt Mask Register 2 — Address 04h

Power on default

<

7:0

>

= 0000 0000 binary

Bit

Name

Read/

Write

Description

0

Hot Temperature

Read/Write

A one disables the corresponding interrupt status bit for INT interrupt.

1

BTI

Read/Write

A one disables the corresponding interrupt status bit for INT interrupt.

2

FAN1

Read/Write

A one disables the corresponding interrupt status bit for INT interrupt.

3

FAN2

Read/Write

A one disables the corresponding interrupt status bit for INT interrupt.

4

CI (Chassis
Intrusion)

Read/Write

A one disables the corresponding interrupt status bit for INT interrupt.

5

OS bit

Read/Write

A one disables the corresponding interrupt status bit for INT interrupt.

6

Hot Temperature
Interrupt mode
select

Read/Write

A zero selects the default interrupt mode which gives the user an interrupt if the
temperature goes above the hot limit. The interrupt will be cleared once the status
register is read, but it will again be generated when the next conversion has completed.
It will continue to do so until the temperature goes below the hysteresis limit.

A one selects the one time interrupt mode which only gives the user one interrupt when
it goes above the hot limit. The interrupt will be cleared once the status register is read.
Another interrupt will not be generated until the temperature goes below the hysteresis
limit. It will also be cleared if the status register is read. No more interrupts will be
generated until the temperature goes above the hot limit again. The corresponding bit
will be cleared in the status register every time it is read but may not set again when the
next conversion is done. (See in Section 7.0)

7

OS bit Interrupt
mode select

Read/Write

A zero selects the default interrupt mode which gives the user an interrupt if the
temperature goes above the hot limit. The interrupt will be cleared once the status
register is read, but it will again be generated when the next conversion has completed.
It will continue to do so until the temperature goes below the hysteresis limit.

A one selects the one time interrupt mode which only gives the user one interrupt when
it goes above the hot limit. The interrupt will be cleared once the status register is read.
Another interrupt will not be generated until the temperature goes below the hysteresis
limit. It will also be cleared if the status register is read. No more interrupts will be
generated until the temperature goes above the hot limit again. The corresponding bit
will be cleared in the status register every time it is read but may not set again when the
next conversion is done. (See Section in Section 7.0)