beautypg.com

Channel slim dsc power supplies – Rainbow Electronics MAX1585 User Manual

Page 20

background image

MAX1584/MAX1585

I

IND(PK)

= 1.25 x I

OUT

/ (1 - D)

Inductance values smaller than L

IDEAL

can be used to

reduce inductor size; however, if much smaller values are
used, inductor current rises and a larger output capaci-
tance might be required to suppress output ripple.

Step-Up Compensation

The inductor and output capacitor are usually chosen
first in consideration of performance, size, and cost.
The compensation resistor and capacitor are then cho-
sen to optimize control-loop stability. In some cases, it
helps to readjust the inductor or output capacitor value
to get optimum results. For typical designs, the compo-
nent values in the circuit of Figure 1 yield good results.

The step-up converter employs current-mode control,
thereby simplifying the control-loop compensation.
When the converter operates with continuous inductor
current (typically the case), a right-half-plane zero
appears in the loop-gain frequency response. To
ensure stability, the control-loop gain should cross over
(drop below unity gain) at a frequency (f

C

) much less

than that of the right-half-plane zero.

The relevant characteristics for step-up channel com-
pensation are as follows:

• Transconductance (from FBSU to CCSU), g

MEA

(135µS)

• Current-sense amplifier transresistance, R

CS

(0.3V/A)

• Feedback regulation voltage, V

FB

(1.25V)

• Step-up output voltage, V

SU

, in V

• Output load equivalent resistance, R

LOAD

, in

Ω = V

SUOUT

/ I

LOAD

The key steps for step-up compensation are as follows:

1) Place f

C

sufficiently below the right-half-plane zero

(RHPZ) and calculate C

C

.

2) Select R

C

based on the allowed load-step transient.

R

C

sets a voltage delta on the C

C

pin that corre-

sponds to load-current step.

3) Calculate the output-filter capacitor (C

OUT

) required

to allow the R

C

and C

C

selected.

4) Determine if C

P

is required (if calculated to be >10pF).

For continuous conduction, the right-half-plane zero fre-
quency (f

RHPZ

) is given by the following:

f

RHPZ

= V

SUOUT

(1 - D)

2

/ (2

π x L x I

LOAD

)

where D = the duty cycle = 1 - (V

IN

/ V

OUT

), L is the

inductor value, and I

LOAD

is the maximum output cur-

rent. Typically, target crossover (f

C

) for 1/6 of the

RHPZ. For example, if we assume f

OSC

= 500kHz, V

IN

= 2.5V, V

OUT

= 5V, and I

OUT

= 0.5A, then R

LOAD

=

10

Ω. If we select L = 4.7µH, then:

f

RHPZ

= 5 (2.5 / 5)

2

/ (2

π x 4.7 x 10

-6

x 0.5) = 84.65kHz

Choose f

C

= 14kHz. Calculate C

C

:

C

C

= (V

FB

/ V

OUT

)(R

LOAD

/ R

CS

)(g

M

/ 2

π x f

C

)(1 - D)

= (1.25 / 5)(10 / 0.3) x (135µS / (6.28 x 14kHz) (2/5)
= 6.4nF

Choose 6.8nF.

Now select R

C

so transient-droop requirements are

met. As an example, if 4% transient droop is allowed,
the input to the error amplifier moves 0.04 x 1.25V, or
50mV. The error-amp output drives 50mV x 135µS, or
6.75µA across R

C

to provide transient gain. Since the

current-sense transresistance is 0.3V/A, the value of R

C

that allows the required load step swing is as follows:

R

C

= 0.3 I

IND(PK)

/ 6.75µA

In a step-up DC-DC converter, if L

IDEAL

is used, output

current relates to inductor current by:

I

IND(PK)

= 1.25 x I

OUT

/ (1 - D) = 1.25 x I

OUT

x V

OUT

/

V

IN

So for a 500mA output load step with V

IN

= 2.5V and

V

OUT

= 5V:

R

C

= [1.25(0.3 x 0.5 x 5) / 2)] / 6.75µA = 69.4k

Note that the inductor does not limit the response in this
case since it can ramp at 2.5V / 4.7µH, or 530mA/µs.

The output filter capacitor is then chosen so the C

OUT

R

LOAD

pole cancels the R

C

C

C

zero:

C

OUT

x R

LOAD

= R

C

x C

C

For the example:

C

OUT

= 68k

Ω x 6.8nF / 10Ω = 46µF

Choose 47µF for C

OUT

. If the available C

OUT

is sub-

stantially different from the calculated value, insert the
available C

OUT

value into the above equation and

recalculate R

C

. Higher substituted C

OUT

values allow a

higher R

C

, which provides higher transient gain and

consequently less transient droop.

If the output filter capacitor has significant ESR, a zero
occurs at the following:

Z

ESR

= 1 / (2

π x C

OUT

x R

ESR

)

5-Channel Slim DSC Power Supplies

20

______________________________________________________________________________________