DS2705: SHA-1 Authentication Master

7 of 18

Figure 2. Typical Application Circuit

DS2705

CHAL

PASS

FAIL

Charge Circuit

Charge Supply

VSS

MDQ

VDD

SDQ

VPP

Charge
Circuit

VSS

Charge

Circuit

VDD

Control

Charge

Circuit

Enable

330

330

1K

150

0.1µF

150

150

150

5.6V

5.6V

18V

VSS

Testpoint

VPP

Testpoint

SDQ

Testpoint

DS2705

Assembly

Programming

Interface

BAT-

Contact

BAT+

Contact

MDQ

Contact

Contacts

from

Charger to

Battery

Pack

BATTERY TOKEN PRESENCE DETECTION

Authentication of a battery or peripheral first depends on the authentication host detecting the presence or insertion
(electrical connection) of the accessory to the host unit. The DS2705 supports insertion detection in four ways, two
use the CHAL pin and two use the MDQ pin:

1. CHAL pin at the active logic level on IC power-up (detected after challenge delay time

t

CHD

). Positive or

negative logic level is determined by the CHP bit.

2. CHAL pin edge trigger after power-up period. Positive or negative edge trigger is determined by the CHP

bit.

3. Detection of Asynchronous 1-Wire Presence Pulse by insertion of battery with 1-Wire device (token).
4. Periodic Authentication Attempt issuing a 1-Wire Reset on MDQ to test for presence of a 1-Wire token.

With cases 1 and 2 above, the CHAL pin acts as a detection trigger when pulled to a logic low or logic high. A split
contact on the battery ground or supply terminal can be used to connect the CHAL pin to the positive or negative
battery terminal when the battery is present. In case 1, when the battery is connected prior to powering up the host
system (which occurs often since the battery typically powers the host), presence is detected by sensing the logic
level on CHAL immediately after power-up of the DS2705. A configuration bit, CHP, allows the use of either polarity
of the CHAL pin. Table 1 shows the timing and sequence of events for detecting presence on power-up. In case 2
above, the DS2705 monitors the CHAL pin for a signal transition after the power-up period is complete. The
DS2705 detects an authentication attempt on a positive or a negative edge of CHAL depending on the state of the
CHP bit. Table 2 shows the timing and sequence of detecting presence with an edge on CHAL.