beautypg.com

Max6613, Detailed description, Table 1. linear and quadratic output equation – Rainbow Electronics MAX6613 User Manual

Page 4

background image

MAX6613

Detailed Description

The MAX6613 analog output temperature sensor’s out-
put voltage is a discrete function of its die temperature.
The maximum supply current is 13µA, and the supply
voltage range is from 2.5V to 5.5V for the -55°C to
+130°C temperature range, or 1.8V to 5.5V for the
+25°C to +130°C temperature range.

Transfer Function

The temperature-to-voltage transfer function is approxi-
mately linear and can be described by the quadratic
equation:

V

OUT

= -0.0000022

T

2

- 0.01105

T + 1.8455V

In many cases, a linear approximation can be applied:

V

OUT

= -0.01123

T + 1.8455V

where T is the die temperature of the MAX6613 in °C.

Therefore:

T = (V

OUT

- 1.8455) / 0.01123V

Compatibility with Other Temperature

Sensors

The MAX6613 can be used to replace temperature sen-
sors using other output algorithms. Table 1 provides
information for a linear and quadratic output equation.
Contact the factory for performance information about
another equation.

Low-Voltage Analog Temperature
Sensor in an SC70 Package

4

_______________________________________________________________________________________

Table 1. Linear and Quadratic Output Equation

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

V

CC

= 2.7V, T

A

= -55°C

2.06

6.57

V

CC

= 2.7V, T

A

= -40°C

1.19

5.73

V

CC

= 2.7V, T

A

= -20°C

0.55

4.36

V

CC

= 2.7V, T

A

= 0°C

0.35

2.85

V

CC

= 2.7V, T

A

= +20°C

-0.37

+2.15

V

CC

= 2.7V, T

A

= +40°C

-1.32

+1.61

V

CC

= 2.7V, T

A

= +60°C

-2.02

+1.92

V

CC

= 2.7V, T

A

= +85°C

-2.32

+1.66

V

CC

= 2.7V, T

A

= +100°C

-2.78

+2.01

V

CC

= 2.7V, T

A

= +125°C

-3.11

+2.54

Temperature Error
Based on:
OUT = 1.8639 - 0.0115

Temp

(Note 4)

V

CC

= 2.7V, T

A

= +130°C

-3.37

+2.90

°C

V

CC

= 2.7V, T

A

= -55°C

1.08

5.76

V

CC

= 2.7V, T

A

= -40°C

0.67

5.33

V

CC

= 2.7V, T

A

= -20°C

0.42

4.28

V

CC

= 2.7V, T

A

= 0°C

0.35

2.85

V

CC

= 2.7V, T

A

= +20°C

-0.49

+1.99

V

CC

= 2.7V, T

A

= +30°C

-0.95

+1.53

V

CC

= 2.7V, T

A

= +40°C

-1.81

+1.05

V

CC

= 2.7V, T

A

= +50°C

-1.93

+0.54

V

CC

= 2.7V, T

A

= +60°C

-3.11

+0.67

V

CC

= 2.7V, T

A

= +85°C

-4.51

-0.74

V

CC

= 2.7V, T

A

= +100°C

-5.77

-1.28

V

CC

= 2.7V, T

A

= +125°C

-7.74

-2.52

Temperature Error
Based on:
OUT = 1.8639 - 0.0115

Temp -

0.00000388

Temp

2

(Note 4)

V

CC

= 2.7V, T

A

= +130°C

-8.35

-2.58

°C