beautypg.com

Rainbow Electronics MAX4880 User Manual

Page 2

background image

MAX4880

Overvoltage-Protection Controller with
Internal Disconnect Switch

2

_______________________________________________________________________________________

ABSOLUTE MAXIMUM RATINGS

ELECTRICAL CHARACTERISTICS

(V

IN

= 5V, T

A

= -40

°C to +85°C, unless otherwise noted. Typical values are at T

A

= +25

°C.) (Note 1)

Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.

(All voltages referenced to GND.)
IN ............................................................................-0.3V to +30V
GATE ......................................................................-0.3V to +12V
EN, CB, FLAGV, BAT_OK, BTA, BTB, BTB_SNS .....-0.3V to +6V
Continuous Power Dissipation (T

A

= +70°C)

10-Pin TDFN (derate 18.5mW/°C above +70°C) ...1481.5mW

Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature .................................................... +150°C
Storage Temperature Range ............................-65°C to +150°C
Lead Temperature (soldering, 10s) ................................+300°C

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

INPUT VOLTAGE (IN)

Input Voltage Range

V

IN

1.2

28.0

V

Overvoltage Trip Level

OVLO

V

IN

rising

5.5

5.6

5.7

V

O ver vol tag e- Tr i p - Level H yster esi s

50

mV

Undervoltage-Lockout Threshold

UVLO

V

IN

falling

4.2

4.35

4.5

V

Undervoltage-Lockout Hysteresis

50

mV

Supply Current

I

IN

+ I

BTA

No load, V

IN

= 5.4V, V

EN

= 0 or 5.5V,

V

CB

= 0 or V

IN

240

380

µA

INTERNAL SWITCH

BTA Input Range

V

BTA

2.8

5.7

V

BTA Undervoltage Lockout

BTA

UVLO

Falling edge

2.4

2.7

V

BTA-Undervoltage-Lockout
Hysteresis

50

mV

BTB-Switch-Disconnect Trip
Level

BTB

TRIP

4.10

4.20

V

BTB-Switch-Disconnect
Hysteresis

200

mV

Switch-Forward Current Limit

I

FWD

450

525

600

mA

T

A

= +25

°C

600

Switch-Reverse Current Limit

I

REV

650

mA

Voltage Drop (V

BTA

– V

BTB

)

I

L

= 400mA

110

mV

BTB Off Current

I

BTB-OFF

V

EN

= 0 ( V

C B

= 0, or V

IN

< V

U V L O

and V

BTA

= 0)

1

µA

GATE

GATE Voltage

V

GATE

I

GATE

sourcing 1µA , V

IN

= 5V

9

10

V

GATE Pulldown Current

I

PD

V

IN

> V

OVLO

, V

GATE

= 5V

60

mA

TIMING

GATE Startup Delay

t

START

V

IN

> V

UVLO

, V

GATE

> 0.3V (Figure 1)

20

50

80

ms

FLAGV Delay Time

t

DELAY

V

GATE

= 0.3V,V

FLAGV

= 2.4V (Figure 1)

20

50

80

ms

GATE Turn-On Time

t

GON

V

GAT E

= 0.3V to 8V , C

GAT E

= 1500p F ( Fi g ur e 1)

7

ms

GATE Turn-Off Time

t

GOFF

V

IN

increasing from 5V to 8V at 3V/µs,

V

GATE

= 0.3V, C

GATE

= 1500pF (Figure 2)

6

20

µs