beautypg.com

Rainbow Electronics MAX6656 User Manual

Page 2

background image

MAX6655/MAX6656

Dual Remote/Local Temperature Sensors and
Four-Channel Voltage Monitors

2

_______________________________________________________________________________________

ABSOLUTE MAXIMUM RATINGS

ELECTRICAL CHARACTERISTICS

(V

CC

= +3.0V to +3.6V for MAX6656, V

CC

= +4.5V to +5.5V for MAX6655, T

A

= -55°C to +125°C, unless otherwise noted. Typical values

are at V

CC

= +3.3V for MAX6656, V

CC

= +5.0V for MAX6655, T

A

= +25°C.)

Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.

V

CC

to GND ..............................................................-0.3V to +6V

DXN_ to GND ........................................................-0.3V to +0.8V
SMBCLK, SMBDATA,

ALERT, STBY,

OVERT to GND.....................................................-0.3V to +6V

V

IN1

to GND............................................................-0.3V to +16V

V

IN2

to GND..............................................................-0.3V to +6V

V

IN3

to GND..............................................................-0.3V to +6V

All Other Pins to GND.................................-0.3V to (V

CC

+ 0.3V)

SMBDATA,

ALERT, OVERT Current....................-1mA to +50mA

DXN_ Current......................................................................±1mA
ESD Protection (all pins, Human Body Model) ..................2000V
Continuous Power Dissipation (T

A

= +70°C)

16-Pin QSOP (derate 8.30mW/°C above +70°C)........667mW

Operating Temperature Range .........................-55°C to +125°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

Supply Range

V

CC

3.0

5.5

V

+60°C

≤ T

A

≤ +100°C

±1.5

Accuracy (Local Sensor)

0°C

≤ T

A

≤ +125°C

±3

°C

+60°C

≤ T

RJ

≤ +100°C

±1

Accuracy (Remote Sensor)

0°C

≤ T

RJ

≤ +120°C

±3

°C

0.125

°C

Temperature Measurement
Resolution

11

Bits

ADC Input Impedance

Z

IN

V

IN1

, V

IN2

, V

IN3

input resistance

100

k

ADC Total Error

V

IN1

, V

IN2

, V

IN3

between 30% and 120% of

nominal

±1

±1.5

%

V

IN

ADC Resolution

8

Bits

Undervoltage Lockout Threshold

UVLO

V

CC

input, disables A/D conversion,

falling edge

2.50

2.70

2.90

V

Undervoltage Lockout
Hysteresis

90

mV

Power-On Reset (POR)
Threshold

V

CC

, falling edge

1

1.7

2.5

V

POR Threshold Hysteresis

90

mV

Standby Current

SMBus static,

STBY = GND

3

10

µA

DXP and DXN Leakage Current

In standby mode

2

µA

Average Operating Current

Continuous temperature mode

550

1000

µA

Conversion Time for Single
Temperature Measurement

t

CON

From stop bit to conversion completed

95

125

155

ms

Monitoring Cycle Time

t

MONI

Total of 3 temperature plus 4 voltage
measurements

625

ms