beautypg.com

Table 6. command byte register map – Rainbow Electronics MAX6656 User Manual

Page 13

background image

MAX6655/MAX6656

Dual Remote/Local Temperature Sensors and

Four-Channel Voltage Monitors

______________________________________________________________________________________

13

REGISTER

ADDRESS

POR STATE

FUNCTION

RLTS

00h

0000 0000

Read Internal Temperature

RRTE

01h

0000 0000

Read External Temperature 1

RSL

02h

0000 0000

Read Status Byte; Note 1

RCL

03h

0000 0000

Read Configuration Byte

RCRA

04h

0000 0010

Read Conversion Rate Byte

RLHN

05h

0111 1111

Read Internal

ALERT High Limit

RLLI

06h

1100 1001

Read Internal

ALERT Low Limit

RRHI

07h

0111 1111

Read External Temperature 1

ALERT High Limit

RRLS

08h

1100 1001

Read External Temperature 1

ALERT Low Limit

WCA

09h

N/A

Write Configuration Byte

WCRW

0Ah

N/A

Write Conversion Rate Control Byte

WLHO

0Bh

N/A

Write Internal

ALERT High Limit

WLLM

0Ch

N/A

Write Internal

ALERT Low Limit

WRHA

0Dh

N/A

Write External Temperature 1

ALERT High Limit

WRLN

0Eh

N/A

Write External Temperature 1

ALERT Low Limit

RRET1

10h

0000 0000

Read External 1 Extended Temperature

RRET2

11h

0000 0000

Read External 2 Extended Temperature

RLET

12h

0000 0000

Read Internal Extended Temperature

RRT2

13h

0000 0000

Read External Temperature 2

RRHL2

14h

0111 1111

Read External Temperature 2

ALERT High Limit

RRLL2

15h

1100 1001

Read External Temperature 2

ALERT Low Limit

RLOL

16h

0111 1111

Read Internal

OVERT Limit

RLOL1

17h

0111 1111

Read External 1

OVERT Limit

RLOL2

18h

0111 1111

Read External 2

OVERT Limit

WLOL

19h

N/A

Write Internal

OVERT Limit

WROL1

1Ah

N/A

Write External 1

OVERT Limit

WROL2

1Bh

N/A

Write External 2

OVERT Limit

WRH2

1Ch

N/A

Write External Temperature 2

ALERT High Limit

WRL2

1Dh

N/A

Write External Temperature 2

ALERT Low Limit

WV0HL

1Eh

N/A

Write V

CC

(V

IN2

)

ALERT High Limit for MAX6655 (MAX6656)

WV0LL

1Fh

N/A

Write V

CC

(V

IN2

)

ALERT Low Limit for MAX6655 (MAX6656)

WV1HL

20h

N/A

Write V

IN1

ALERT High Limit

WV1LL

21h

N/A

Write V

IN1

ALERT Low Limit

WV2HL

22h

N/A

Write V

IN2

(V

CC

)

ALERT High Limit for MAX6655 (MAX6656)

WV2LL

23h

N/A

Write V

IN2

(V

CC

)

ALERT Low Limit for MAX6655 (MAX6656)

WV3HL

24h

N/A

Write V

IN3

ALERT High Limit

WV3LL

25h

N/A

Write V

IN3

ALERT Low Limit

RV0HL

26h

1101 0011

Read V

CC

(V

IN2

)

ALERT High Limit for MAX6655 (MAX6656)

RV0LL

27h

1010 1101

Read V

CC

(V

IN2

)

ALERT Low Limit for MAX6655 (MAX6656)

Table 6. Command Byte Register Map