Table 8. configuration byte 2 bit assignments, Table 9. status byte 1 bit assignments – Rainbow Electronics MAX6656 User Manual
Page 15
MAX6655/MAX6656
Dual Remote/Local Temperature Sensors and
Four-Channel Voltage Monitors
______________________________________________________________________________________
15
BIT
NAME
POR
STATE
FUNCTION
7 (MSB)
Disable Remote
Temperature 1
Measurement
0
If high, the remote temperature 1 measurement is disabled.
6
Disable Remote
Temperature 2
Measurement
0
If high, the remote temperature 2 measurement is disabled.
5
Disable Internal
Temperature
Measurement
0
If high, the internal temperature measurement is disabled.
4
Disable V
IN3
Measurement
0
If high, the input voltage V
IN3
measurement is disabled.
3
Disable V
IN2
Measurement
0
If high, the input voltage V
IN2
(V
CC
) measurement is disabled for MAX6655
(MAX6656).
2
Disable V
IN1
Measurement
0
If high, the input voltage V
IN1
measurement is disabled.
1
Disable V
CC
Measurement
0
If high, the input voltage V
CC
(V
IN2
) measurement is disabled for MAX6655
(MAX6656).
0
Reserved
0
Reserved for future use.
Table 8. Configuration Byte 2 Bit Assignments
BIT
NAME
POR STATE
FUNCTION
7 (MSB)
BUSY
0
ADC is busy converting when high.
6
LHIGH
0
Internal high-temperature
ALERT has tripped when high; cleared by POR or
readout of the entire Status Byte.
5
LLOW
0
Internal low-temperature
ALERT has tripped when high; cleared by POR or
readout of the entire Status Byte.
4
RHIGH
0
External 1 high-temperature
ALERT has tripped when high; cleared by POR or
readout of the entire Status Byte.
3
RLOW
0
External 1 low-temperature
ALERT has tripped when high; cleared by POR or
readout of the entire Status Byte.
2
DODS1
0
A high indicates external diode 1 open/short.
1
R2HIGH
0
External 2 high-temperature
ALERT has tripped when high; cleared by POR or
readout of the entire Status Byte.
0
R2LOW
0
External 2 low-temperature
ALERT has tripped when high; cleared by POR or
readout of the entire Status Byte.
Table 9. Status Byte 1 Bit Assignments