Rainbow Electronics MAX6692 User Manual

Page 7

background image

MAX6648/MAX6692

Precision SMBus-Compatible Remote/Local

Temperature Sensors with Overtemperature Alarms

_______________________________________________________________________________________

7

2) If the MAX6648/MAX6692 are in run mode, read the

status byte. If the BUSY bit indicates that a conversion
is in progress, wait until the conversion is complete
(BUSY bit set to zero) before reading the temperature
data. Following a conversion completion, immediately

read the contents of the temperature data registers. If
no conversion is in progress, the data can be read
within a few microseconds, which is a sufficiently short
period of time to ensure that a new conversion cannot
be completed until after the data has been read.

SMBCLK

A

B

C

D

E

F

G

H

I

J

K

SMBDATA

t

SU:STA

t

HD:STA

t

LOW

t

HIGH

t

SU:DAT

t

HD:DAT

t

SU:STO

t

BUF

A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW

L

M

F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
I = MASTER PULLS DATA LINE LOW

J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION

Figure 2. SMBus Write Timing Diagram

Write Byte Format

Read Byte Format

Send Byte Format

Receive Byte Format

Slave Address: equiva-
lent to chip-select line of
a 3-wire interface

Command Byte: selects which
register you are writing to

Data Byte: data goes into the register
set by the command byte (to set
thresholds, configuration masks, and
sampling rate)

Slave Address: equiva-
lent to chip-select line

Command Byte: selects
which register you are
reading from

Slave Address: repeated
due to change in data-
flow direction

Data Byte: reads from
the register set by the
command byte

Command Byte: sends com-
mand with no data, usually
used for one-shot command

Data Byte: reads data from
the register commanded
by the last Read Byte or
Write Byte transmission;
also used for SMBus Alert
Response return address

S = Start condition

Shaded = Slave transmission

P = Stop condition

/// = Not acknowledged

Figure 1. SMBus Protocols

S

ADDRESS

RD

ACK

DATA

///

P

7 bits

8 bits

WR

S

ACK

COMMAND

ACK

P

8 bits

ADDRESS

7 bits

P

1

ACK

DATA

8 bits

ACK

COMMAND

8 bits

ACK

WR

ADDRESS

7 bits

S

S

ADDRESS

WR

ACK

COMMAND

ACK

S

ADDRESS

7 bits

8 bits

7 bits

RD

ACK

DATA

8 bits

///

P