Table 5. command-byte bit assignments, Table 6. configuration-byte bit assignments (03h) – Rainbow Electronics MAX6692 User Manual
Page 10
MAX6648/MAX6692
Precision SMBus-Compatible Remote/Local
Temperature Sensors with Overtemperature Alarms
10
______________________________________________________________________________________
equipment applications. The conversion rate byte’s
POR state is 07h or 4Hz. The MAX6648/MAX6692 look
only at the 3 LSBs of this register, so the upper 5 bits
are don’t care bits, which should be set to zero. The
conversion rate tolerance is ±25% at any rate setting.
Valid A/D conversion results for both channels are avail-
able one total conversion time (125ms nominal, 156ms
maximum) after initiating a conversion, whether conver-
sion is initiated through the RUN bit, one-shot com-
mand, or initial power-up. Changing the conversion rate
can also affect the delay until new results are available.
Slave Addresses
The MAX6648/MAX6692 have a fixed address of 1001
100. The MAX6648/MAX6692 also respond to the
SMBus alert response slave address (see the Alert
Response Address section).
REGISTER
ADDRESS
POR STATE
FUNCTION
RLTS
00h
0000 0000
0°C
Read local (internal) temperature
RRTE
01h
0000 0000
0°C
Read remote (external) temperature
RSL
02h
N/A
—
Read status byte
RCL
03h
0000 0000
—
Read configuration byte
RCRA
04h
0000 0111
—
Read conversion rate byte
RLHN
05h
0101 0101
+85°C
Read local (internal) ALERT high limit
RLLI
06h
0000 0000
0°C
Read local (internal) ALERT low limit
RRHI
07h
0101 0101
+85°C
Read remote (external) ALERT high limit
RRLS
08h
0000 0000
0°C
Read remote (external) ALERT low limit
WCA
09h
N/A
—
Write configuration byte
WCRW
0Ah
N/A
—
Write conversion rate byte
WLHO
0Bh
N/A
—
Write local (internal) ALERT high limit
WLLM
0Ch
N/A
—
Write local (internal) ALERT low limit
WRHA
0Dh
N/A
—
Write remote (external) ALERT high limit
WRLN
0Eh
N/A
—
Write remote (external) ALERT low limit
OSHT
0Fh
N/A
—
One-shot
REET
10h
0000 0000
0°C
Read remote (external) extended temperature
RIET
11h
0000 0000
0°C
Read local (internal) extended temperature
0110 1110
+110°C
Read/write remote (external) OVERT limit (MAX6648)
RWOE
19h
0101 0101
+85°C
Read/write remote (external) OVERT limit (MAX6692)
RWOI
20h
0101 0101
+85°C
Read/write local (internal) OVERT limit
HYS
21h
0000 1010
10°C
Overtemperature hysteresis
QUEUE
22h
1000 0000
—
Fault queue
—
FEh
0100 1101
—
Read manufacture ID
—
FFh
0101 1001
—
Read revision ID
Table 5. Command-Byte Bit Assignments
BIT
NAME
POR STATE
FUNCTION
7 (MSB)
MASK
0
Masks ALERT interrupts when set to 1.
6
RUN
0
Standby mode control bit; if set to 1, standby mode is initiated.
5 to 0
RFU
0
Reserved.
Table 6. Configuration-Byte Bit Assignments (03h)