beautypg.com

Electrical characteristics (continued) – Rainbow Electronics MAX6659 User Manual

Page 3

background image

MAX6657/MAX6658/MAX6659

_______________________________________________________________________________________

3

Note 1: T

A

= +25°C to +85°C.

Note 2: If both the local and the remote junction are below T

A

= -20°C, then V

CC

> 3.15V.

Note 3: For conversion rates of 4Hz or slower, the conversion time doubles.
Note 4: Timing specifications guaranteed by design.
Note 5: The serial interface resets when SMBCLK is low for more than t

TIMEOUT

.

Note 6: A transition must internally provide at least a hold time to bridge the undefined region (300ns max) of SMBCLK's falling edge.

ELECTRICAL CHARACTERISTICS (continued)

(Circuit of Typical Operating Circuit, V

CC

= +3.0V to +5.5V, T

A

= 0°C to +125°C, unless otherwise specified. Typical values are at

V

CC

= +3.3V and T

A

= +25°C.)

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

Conversion Time

t

CONV

From stop bit to conversion completed
(Note 4)

95

125

156

ms

Conversion Timing Error

±25

%

DXP and DXN Leakage Current

In standby mode

100

nA

High level

80

100

120

Remote-Diode Source Current

I

RJ

Low level

8

10

12

µA

(

ALERT, OVERT)

V

OL

= 0.4V

1

Output Low Sink Current

V

OL

= 0.6V

6

mA

Output High Leakage Current

V

OH

= 5.5V

1

µA

SMBus-COMPATIBLE INTERFACE (SMBCLK, SMBDATA,

STBY)

Logic Input Low Voltage

V

IL

0.8

V

V

CC

= +3.0V

2.2

Logic Input High Voltage

V

IH

V

CC

= +5.5V

2.4

V

Input Leakage Current

I

LEAK

V

IN

= GND or V

CC

±1

µA

Output Low Sink Current

I

OL

V

OL

= 0.6V

6

mA

Input Capacitance

C

IN

5

pF

SMBus-COMPATIBLE TIMING (Note 4)

Serial Clock Frequency

f

SCL

(Note 5)

100

kHz

Bus Free Time Between STOP
and START Condition

t

BUF

4.7

µs

START Condition Setup Time

4.7

µs

Repeat START Condition Setup
Time

t

SU:STA

90% to 90%

50

ns

START Condition Hold Time

t

HD:STA

10% of SMBDATA to 90% of SMBCLK

4

µs

STOP Condition Setup Time

t

SU:STO

90% of SMBCLK to 90% of SMBDATA

4

µs

Clock Low Period

t

LOW

10% to 10%

4.7

µs

Clock High Period

t

HIGH

90% to 90%

4

µs

Data Setup Time

t

HD:DAT

(Note 6)

0

µs

Receive SCL/SDA Rise Time

t

R

1

µs

Receive SCL/SDA Fall Time

t

F

300

ns

Pulse Width of Spike Suppressed

t

SP

0

50

ns

SMBus Timeout

SMBDATA low period for interface reset

25

37

45

ms

±1°C, SMBus-Compatible Remote/Local Temperature

Sensors with Overtemperature Alarms