Page 10

background image

MAX6657/MAX6658/MAX6659

1) Put the MAX6657/MAX6658/MAX6659 into standby

mode by setting bit 6 of the Configuration register to
1. Initiate a one-shot conversion using Command
Byte 0Fh. When this conversion is complete, read
the contents of the Temperature Data registers.

2) If the MAX6657/MAX6658/MAX6659 are in run mode,

read the Status register. If a conversion is in
progress, the BUSY bit is set to 1. Wait for the con-
version to complete as indicated by the BUSY bit
being set to 0, then read the Temperature Data reg-
isters. Note that the power-on reset sets the conver-

sion rate to 16Hz, so no extended data is valid with-
out reducing the conversion rate to 4Hz or less.

Diode Fault Alarm

There is a continuity fault detector at DXP that detects
an open circuit between DXP and DXN, or a DXP short
to V

CC

, GND, or DXN. If an open or short circuit exists,

the external temperature register is loaded with 1000
0000. Additionally, if the fault is an open circuit, bit 2
(OPEN) of the status byte is set to 1 and the ALERT con-
dition is activated at the end of the conversion.
Immediately after POR, the Status register indicates that
no fault is present until the end of the first conversion.

10

______________________________________________________________________________________

SMBCLK

A

B

C

D

E

F

G

H

I

J

K

SMBDATA

t

SU:STA

t

HD:STA

t

LOW

t

HIGH

t

SU:DAT

t

HD:DAT

t

SU:STO

t

BUF

L

M

A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW

F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
I = MASTER PULLS DATA LINE LOW

J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION

Figure 4. SMBus Read Timing Diagram

SMBCLK

A

B

C

D

E

F

G

H

I

J

K

SMBDATA

t

SU:STA

t

HD:STA

t

LOW

t

HIGH

t

SU:DAT

t

HD:DAT

t

SU:STO

t

BUF

A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW

L

M

F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = MASTER PULLS DATA LINE LOW

J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION
M = NEW START CONDITION

Figure 3. SMBus Write Timing Diagram

±1°C, SMBus-Compatible Remote/Local Temperature
Sensors with Overtemperature Alarms