Absolute maximum ratings, Electrical characteristics – Rainbow Electronics MAX6659 User Manual
Page 2
MAX6657/MAX6658/MAX6659
2
_______________________________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
All Voltages Referenced to GND
V
CC
..........................................................................-0.3V to +6V
DXP ............................................................-0.3V to (V
CC
+ 0.3V)
DXN ......................................................................-0.3V to +0.8V
SMBCLK, SMBDATA,
ALERT, OVERT1,
OVERT2 ..............................................................-0.3V to +6V
SMBDATA,
ALERT, OVERT1, OVERT2
Current ..........................................................-1mA to +50mA
DXN Current ......................................................................±1mA
Continuous Power Dissipation (T
A
= +70°C)
8-Pin SO (derate 5.9mW/°C above +70°C) .................471mW
16-Pin QSOP (derate 8.3mW/°C above +70°C) ..........664mW
Junction Temperature .....................................................+150°C
Storage Temperature Range ............................-65°C to +150°C
Lead Temperature (soldering, 10s) ................................+300°C
ELECTRICAL CHARACTERISTICS
(Circuit of Typical Operating Circuit, V
CC
= +3.0V to +5.5V, T
A
= 0°C to +125°C, unless otherwise specified. Typical values are at
V
CC
= +3.3V and T
A
= +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
1
°C
Temperature Resolution,
Legacy Mode
8
Bits
0.125
°C
Temperature Resolution,
Extended Mode
11
Bits
T
RJ
= +60°C to +100°C, V
CC
= +3.3V
(Note 1)
-1.0
+1.0
T
RJ
= 0°C to +100°C, V
CC
= +3.3V (Note 1)
-3.0
+3.0
Remote Temperature Error
(MAX6657)
T
RJ
= 0°C to +125°C, V
CC
= +3.3V (Note 1)
-5.0
+5.0
°C
T
A
= +60°C to +100°C, V
CC
= +3.3V
-2.0
+2.0
T
A
= 0°C to +100°C, V
CC
= +3.3V
-3.0
+3.0
Local Temperature Error
(MAX6657)
T
A
= 0°C to +125°C, V
CC
= +3.3V
-5.0
+5.0
°C
T
RJ
= +60°C to +100°C, V
CC
= +3.3V
(Note 1)
-1.0
1.0
T
RJ
= 0°C to +100°C, V
CC
= +3.3V (Note 1)
-3.0
3.0
Remote Temperature Error
(MAX6658/MAX6659)
T
RJ
= -55°C to +125°C, V
CC
= +3.3V (Note 1)
-5.0
+5.0
°C
T
A
= +60°C to +100°C, V
CC
= +3.3V
-2.0
+2.0
T
A
= 0°C to +100°C, V
CC
= +3.3V
-3.0
+3.0
Local Temperature Error
(MAX6658/MAX6659)
T
A
= -55°C to +125°C, V
CC
= +3.3V (Note 2)
-5.0
+5.0
°C
Line Regulation
3.0V
≤ V
CC
≤ 5.5V
0.2
0.6
m°C/V
Supply Voltage Range
V
CC
3.0
5.5
V
Undervoltage Lockout Threshold
UVLO
Falling edge of V
CC
disables ADC
2.60
2.80
2.95
V
Undervoltage Lockout Hysteresis
90
mV
Power-On Reset (POR) Threshold
V
CC
, falling edge
1.5
2.0
2.5
V
POR Threshold Hysteresis
90
mV
Standby Supply Current
SMBus static
3
10
µA
Operating Current
During conversion
0.5
1.0
mA
0.25 conversions/s
40
70
Average Operating Current
2 conversions/s
150
250
µA
±1°C, SMBus-Compatible Remote/Local Temperature
Sensors with Overtemperature Alarms