11

Expression pedal input continued

Resetting parameters and parameter ranges

To reset the parameters and parameter ranges assigned to a Flash-
back X4 Delay & Looper preset, proceed as follows:

– Connect an expression pedal to the

EXP PEDAL

jack on the

Flashback X4 Delay & Looper.

– Switch on the Flashback X4 Delay & Looper.

– Choose the respective preset (A, B or C) on the Flashback X4

Delay & Looper.

– Set the expression pedal to the maximum position.

– Press and hold the footswitch for the preset.

– Set the knobs for the parameters you want to control to the

desired maximum values.

– Set the expression pedal to the minimum position.

– Set the knobs for the parameters you want to control to the

desired minimum values.

– Press and hold the footswitch for the preset to store these

settings.