beautypg.com

Peerless Water 30 CME Series - Service Manual User Manual

Page 7

background image

User (U) Displays/Settings

When the system is operating one of two displays will be shown. Pressing NEXT will alternate between the
displays. One of the displays is always the current time of day. The second display is one of the following: days
remaining or gallons remaining. Days remaining are the number of days left before the system goes through a
regeneration cycle. Capacity remaining is the number of gallons that will be treated before the system goes
through a regeneration cycle. The user can scroll between the displays as desired.

If the system has called for a regeneration that will occur at the preset time of regeneration, the words REGEN
TODAY will appear on the display.

When water is being treated (i.e. water is flowing through the system) the word “Softening” flashes on the
display.

Note: If brine tank does not contain salt, fill with salt and wait at least two hours before regenerating.

REGENERATION MODE

Typically a system is set to regenerate at a time of low water usage. An example of a time with low water
usage is when a household is asleep. If there is a demand for water when the system is regenerating,
untreated water will be used.

When the system begins to regenerate, the display will change to include information about the step of the
regeneration process and the time remaining for that step to be completed. The system runs through the steps
automatically and will reset itself to provide treated water when the regeneration has been completed.

MANUAL REGENERATION

Sometimes there is a need to regenerate the system, sooner than when the system calls for it, usually referred
to as manual regeneration. There may be a period of heavy water usage because of guests or a heavy laundry
day. To initiate a manual regeneration at the preset delayed regeneration time, when the regeneration time
option is set to “NORMAL” or “NORMAL + on 0”, press and release “REGEN”. The words “REGEN TODAY”
will flash on the display to indicate that the system will regenerate at the preset delayed regeneration time. If
you pressed the “REGEN” button in error, pressing the button again will cancel the request. Note: If the
regeneration time option is set to “on 0” there is no set delayed regeneration time so “REGEN TODAY” will not
activate if “REGEN” button is pressed. To initiate a manual regeneration immediately, press and hold the
“REGEN” button for three seconds. The system will begin to regenerate immediately. The request cannot be
cancelled.