beautypg.com

Peerless Water 30 CME Series - Service Manual User Manual

Page 5

background image

START UP PROCEDURE

PEERLESS CME WATER SOFTENER

1. Pipe ¾” or 1” inlet and outlet service piping, according to the print, and arrows on bypass.

2. Connect brine line (furnished in brine tank) from brine tank to valve. Line must be air tight.

3. Connect 5/8” OD poly tubing (not supplied) from valve to suitable drain. DO NOT use clear collapsible tubing.

4. With the bypass valve in the bypass position, open a cold water tap nearby and let it run a few minutes. Once free from
air, close tap. Partly open bypass to allow water to slowly fill tank. Once water stops running into the tank, rotate the
bypass valve into the full service position. Again, open a cold water tap nearby and let the water run until the water is
clear and free of air.

5. Plug the unit into an approved 120V AC outlet. Press the Set Clock button once and hour will flash. Use the up or
down triangle buttons until the correct hour is displayed. Press the Set Clock button again and the minutes will flash.
Use the up or down triangle buttons until the correct minutes are displayed. Press the Set Clock button to finish.

NOTE:

Time of day must be set correctly to either AM or PM.

6A. Test the raw water, and set computed grains of hardness expressed as gpg (grains per gallon), and iron expressed as
ppm (parts per million) Do not forget to compensate for iron. The iron result in ppm should be rounded up to the nearest
whole number. Take that number and times it by four (4). Take that result and add it to the hardness value. This is the
number you will use to set up your control for your specific requirements.

NOTE:

If your iron result is higher than 5 ppm, we recommend an iron filter be installed before the softener. If

an iron filter is installed, or you do not have any iron in your water, you do not have to compensate for iron when
setting up the control for your specific requirements.

B .To set the total hardness in the unit, press the Next and Up triangle buttons at the same time. The display will show
Hardness. Press the Up or Down triangle to enter your total hardness result from stop 6.A.
C. Press the Next button, and the display will show Regen Day. The factory default is set at 7. Please do not change
this value.
D. Press the Next button, and the display will show Time Regen. The factory default is set at 2:00 A.M. Press the Up
or Down triangle to change the hour. Press the Next button and the minutes will flash. To change press the Up or Down
triangle to change the minutes. Press the Next button to finish.

7. Manually add water to brine tank until water is ½” above the grid.

8A. Press and hold the Regen button for 5 seconds. Release when display shows backwash. Let the water run for 5
minutes.
B. Press the Regen button and release. The display will show Brine. Wait 1 minute.
C. Press the Regen button and release. The display will show Backwash. Wait 1 minute.
D. Press the Regen button and release. The display will show Rinse. Wait one 1 minute.
E. Press the Regen button and release. The display will show Fill. Push down on the float rod to purge air from the brine
line.

9. Fill brine tank with salt. Peerless recommends Hardi-Cube, Dura-Cube or Mini-Cube or salt substitutes, i.e. Potassium
Chloride, (trade names) K-Life or Soft Touch.

10. Open the cold water valves in house to relieve air. Let water run for 3 minutes and test cold water to make sure it is
soft.

11. Hot water from the water heater (unless drained and filled with soft water) will not become soft until the customer has
used approximately 3 times the holding capacity of the water heater.

12. Write the installation date (month/year) on the sticker found inside the front cover. Plug in 9V Alkaline Battery that
is supplied with your unit