beautypg.com

Peerless Water 30 CME Series - Service Manual User Manual

Page 4

background image

S

pecifications:

Rough in Dimension - From the floor to the center of bypass approximately 50-1/2”.
Maxium distance and size for Drain line: 50’ horizontal, 10’ vertical rise, using 1/2” ID drain line.

Maxium distance and size for Brine line: 15’ horizontal, (see note), using 1/4” ID poly tubing.

Note: The horizontal distance for the Brine tank can be increased to 35’ if the Brine tank is installed
above the unit. Example: Softener installed in the basement and Brine tank installed on 1st floor.
The brine tank can Not

be installed below bottom of unit. The Drain and Brine lines should Not

be

installed with tubing that can collapse. This will cause the unit to malfunction.

Caution: Do Not

connect drain line tubing from control valve to over flow fitting/tubing on brine

tank.