11. Roof Truss Details

PNEG-1092 30° Bin Roof Construction

73

Temperature Cable Support Packages for Eave Heights of
40'-5'' or Less (12.32 m) Installation

CRP-5423 (27'-33' (8.23 m-10.06 m) Support System) and
CRP-5424 (36'-42' (10.97 m-12.80 m) Support System)

1. All 27' through 42' (8.23 m-12.80 m) packages shall span one roof panel as shown in

Figure 11I

on Page 74

.

2. A rafter support system (included in each package) will be necessary for temperature cable

installation in farm tanks 27' (8.23 m) to 42' (12.80 m) in diameters that have an eave height less than
40'-4" (12.29 m).

3. One package should be provided for each cable in the tank with the exception of the center cable.

4. All packages include hanging angles and a cable support channel.

5. Each set of rafters should carry only one temperature cable.

6. Kit CRP-5424 contains two (2) rafter sections which splice together with CRP-5262. Kit CRP-5423

contains only one rafter section.

7. (CRP-5424 ONLY) Center the support angle on the outside of the rafter and field drill the holes to

bolt the support angle (CRP-5422) (36'-42' (10.97 m-12.80 m)) to the roof rafter (

See Figure 11J on

Page 75

to locate which holes to drill) and attach with 3/8" diameter bolts.

8. (CRP-5424 ONLY) Should the angle location be such that the rafter splice coincides with angle

placement, the angle should be slid one way enough to align the angle holes with the splice
bolts or miss the splice bolts. (If angle is to be bolted over splice, remove splice plate before
installing angle.)

9. Once the rafters are in place, field drill the holes to bolt the support angles (CRP-5786 or

CRP-5787) into the roof rafter

(See Figure 11I on Page 74)

and attach with 3/8" diameter bolts.

10. Attach the cable attachment bracket (CRP-5213) in the center of the support channel (CRP-5419) as

illustrated in

Figure 11I on Page 74

and hang the cable.

11. If it is desired to support the cable from the flange of the support channel (CRP-5419), it will be

necessary to reinforce the flange with a 12" section of 3" x 3" x 3/16" angle.

12. No more than one cable should be supported from a pair of roof rafters.

13. This package will allow a maximum radius of: (27' equals 11.84') (8.23 m equals 3.61 m), (30' equals

13.15') (9.14 m equals 4.01 m), (33' equals 14.00') (10.06 m equals 4.27 m), (36' equals 15.29')
(10.97 m equals 4.66 m), (42' equals 17.84') (12.80 m equals 5.44 m). These radii represent the
maximum radius that the cross members will span. These are not recommended installation
locations. Install according to the temperature cable manufacturer’s recommendations. For a greater
radius, the recommendation shown in this manual for temperature cable installation must be used
(using field cut, hot rolled sections), however a rafter support package must still be used.